IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 50/60Hz coil, w/o cover
LC1D80U7M
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Environment

Product Certifications
BV || CCC || CSA || DNV || GL || LROS (Lloyds register of shipping) || UL || GOST || RINA || UKCA
Height
127 mm
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Climatic Withstand
IACS E10 exposure to damp heat
Net Weight
1.59 kg
Flame Retardance
V1 conforming to UL 94
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || shocks contactor closed 10 Gn for 11 ms)
Operating Altitude
0...9842.52 ft (0...3000 m)
Fire Resistance
850 °C IEC 60695-2-1
Width
85 mm
Depth
130 mm
Permissible Ambient Air Temperature Around The Device
-40-60 °C || 60-70 °C with derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110205EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A
Eu Rohs Directive
Compliant

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
Power Dissipation Per Pole
12.5 W AC-1 || 5.1 W AC-3
Average Impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
125 A (at 60 °C) for power circuit || 10 A (at 60 °C) for signalling circuit
Control Circuit Voltage Limits
0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55 °C operational AC 50 Hz || 0.85...1.1 Uc -40-55 °C operational AC 60 Hz || 1...1.1 Uc 55-70 °C operational AC 50/60 Hz
Mounting Support
plate || rail
Contact Compatibility
M11
Control Circuit Type
AC 50/60 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree
3
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
1100 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating
200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for signalling circuit conforming to IEC 60947-5-1
Inrush Power In Va
245-245 VA 60 Hz cos phi 0.75 (at 20 °C) || 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947
Pole Contact Composition
3 NO
Connections - Terminals
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid || power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end || power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end || power circuit: connector 1 4-50 mm² - cable stiffness: solid || power circuit: connector 2 4-25 mm² - cable stiffness: solid || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology
without built-in suppressor module
Operating Time
6...20 ms opening || 20...35 ms closing
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h 60 °C
Signalling Circuit Frequency
25...400 Hz
Tightening Torque
power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Electrical Durability
1.5 Mcycles 80 A AC-3 <= 440 V || 0.8 Mcycles 125 A AC-1 <= 440 V
Mechanical Durability
4 Mcycles
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Compatibility Code
LC1D
Hold-In Power Consumption In Va
26-26 VA 60 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
Overvoltage Category
III
Maximum Horse Power Rating
20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 25 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Motor Power Kw
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 kW at 220...230 V AC 50/60 Hz (AC-3e) || 37 kW at 380...400 V AC 50/60 Hz (AC-3e) || 45 kW at 415...440 V AC 50/60 Hz (AC-3e) || 55 kW at 500 V AC 50/60 Hz (AC-3e) || 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
[Ui] Rated Insulation Voltage
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || signalling circuit 690 V IEC 60947-1
[Icw] Rated Short-Time Withstand Current
135 A 40 °C - 10 min for power circuit || 320 A 40 °C - 1 min for power circuit || 640 A 40 °C - 10 s for power circuit || 990 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Heat Dissipation
6-10 W at 50/60 Hz
Protective Cover
without

Specifications

[Uc] Control Circuit Voltage
240 V AC 50/60 Hz
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz
Range Of Product
TeSys Deca
Contactor Application
motor control || resistive load
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-3 || AC-3e || AC-4 || AC-1
[Ie] Rated Operational Current
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Poles Description
3P
Device Short Name
LC1D

Documents

Data Sheet

Download

Related products