contactor body withou coil, TeSys F, 3P(3NO), AC-3, <=440V 1000A, with coil LX1/LX9, 110…500V AC 40/400Hz, LX4 - 110...440V DC
LC1F1000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
41 626,26 zł

Additional Information

Part Number
LC1F1000
UNSPSC
39121529
Tariff Code
8536490080

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open6 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Ambient Air Temperature For Operation
-5-40 °C
Height
332 mm
Net Weight
31 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Width
438 mm
Depth
238.6 mm
Permissible Ambient Air Temperature Around The Device
-40-60 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110206EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1102006EN
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
CB || CSA || CCC || UKCA
Power Dissipation Per Pole
200 W AC-1
Average Impedance
0.1 mOhm - Ith 1250 A 50 Hz
Control Circuit Voltage Limits
operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.35 Uc DC with LX4 coil
[Ith] Conventional Free Air Thermal Current
1250 A (at 40 °C)
Standards
EN 60947-4-1 || IEC 60947-4-1 || EN 60947-1 || IEC 60947-1
[Uc] Control Circuit Voltage
110...500 V AC 40...400 Hz with LX1/LX9 coil || 110...440 V DC with LX4 coil
Mounting Support
plate
Rated Breaking Capacity
8 kA conforming to IEC 60947-4-1
Irms Rated Making Capacity
10 kA AC conforming to IEC 60947-4-1
Power Range
315-315 kW 220-230 V 3 phase || 560-560 kW 380-400 V 3 phase || 630-630 kW 415-415 V 3 phase || 670-670 kW 440-440 V 3 phase
Associated Fuse Rating
2000 A gG at <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
1600-2400 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 2000-2200 VA (at 20 °C)with LX4 coil
Connections - Terminals
power circuit bar 4 || power circuit bar 3 || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm²
Maximum Operating Rate
600 cyc/h 55 °C
Operating Time
40...75 ms closing with LX1/LX9 coil || 100...170 ms opening with LX1/LX9 coil || 50...60 ms closing with LX4 coil || 45...60 ms opening with LX4 coil
Tightening Torque
power circuit 58 N.m || control circuit 1.2 N.m
Mechanical Durability
0.5 Mcycles
Compatibility Code
LC1F
Hold-In Power Consumption In Va
29-37 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 8-10 VA (at 20 °C)with LX4 coil
Overvoltage Category
III
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
7500 A 40 °C - 30 s || 5500 A 40 °C - 1 min || 4200 A 40 °C - 3 min || 3000 A 40 °C - 10 min || 10000 A 40 °C - 10 s
Heat Dissipation
18-18 W

Specifications

[Ue] Rated Operational Voltage
<= 440 V AC 50/60 Hz
Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Product Name
TeSys F
Range
TeSys
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
1250 A 40 °C) <= 440 V AC AC-1 || 1000 A 55 °C) <= 440 V AC AC-3
Utilisation Category
AC-3 || AC-1
Poles Description
3P
Device Short Name