contactor body withou coil, TeSys F, 3P(3NO), AC-1 <=440V 1260A with coil LX1/ LX9, 110…600V AC 40/400Hz, LX4, 48…250V DC
LC1F1250
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
€1,526.58

Additional Information

Part Number
LC1F1250
UNSPSC
39121529
Tariff Code
8536490065
Country of Origin
CZ

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open6 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Ambient Air Temperature For Operation
-5-40 °C
Height
338 mm
Net Weight
19 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Operating Altitude
9842.52 ft (3000 m) without derating
Width
309 mm
Depth
255 mm
Permissible Ambient Air Temperature Around The Device
-40-60 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1505009EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1505009EN
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
CB || UL || CSA || CQC || CE || UKCA || CCC
Power Dissipation Per Pole
120 W AC-1
Average Impedance
0.12 mOhm - Ith 1260 A 50 Hz
Control Circuit Voltage Limits
operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.35 Uc DC with LX4 coil
[Ith] Conventional Free Air Thermal Current
1260 A (at 40 °C)
Standards
IEC 60947-1 || EN 60947-1 || JIS C8201-4-1 || EN 60947-4-1 || IEC 60947-4-1
[Uc] Control Circuit Voltage
110...600 V AC 40...400 Hz with LX1/LX9 coil || 28...250 V DC with LX4 coil
Mounting Support
plate
Rated Breaking Capacity
1890 A conforming to IEC 60947-4-1
Irms Rated Making Capacity
1890 A conforming to IEC 60947-4-1
Associated Fuse Rating
1400 A gG at <= 440 V for power circuit
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
1500-1730 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 1420-1920 VA (at 20 °C)with LX4 coil
Connections - Terminals
power circuit bar 2 || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm²
Maximum Operating Rate
1200 cyc/h 55 °C
Operating Time
40...80 ms closing with LX1/LX9 coil || 100...200 ms opening with LX1/LX9 coil || 60...70 ms closing with LX4 coil || 40...50 ms opening with LX4 coil
Tightening Torque
power circuit 58 N.m || control circuit 1.2 N.m
Mechanical Durability
1 Mcycles
Hold-In Power Consumption In Va
20-25 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 6.5-12.5 VA (at 20 °C)with LX4 coil
Overvoltage Category
III
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
3000 A 40 °C - 3 min || 5200 A 40 °C - 30 s || 4000 A 40 °C - 1 min || 2000 A 40 °C - 10 min || 8000 A 40 °C - 10 s
Heat Dissipation
20-20 W

Specifications

[Ue] Rated Operational Voltage
<= 690 V AC 50/60 Hz
Contactor Application
resistive load
Product Or Component Type
contactor
Product Name
TeSys F
Range
TeSys
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
1260 A 40 °C) <= 440 V AC-1
Utilisation Category
AC-1
Poles Description
3P
Device Short Name
LC1F

Documents

Data Sheet

Download

CAD Models

Trace parts
Trace parts
Download