Schneider Electric
LC1G150BEEA
Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 150A, 3 pole/NO, 24-48VAC/DC coil
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
€554.09
1
Payment methods:
A total of 6 Parts In-Stock from 10 Distributors
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Additional Information
- Part Number
- LC1G150BEEA
- UNSPSC
- 39121529
- Tariff Code
- 8536410045
Complementary
- Product Certifications
- CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
- Height
- 255 mm
- Power Dissipation Per Pole
- 10 W AC-1 - Ith 275 A || 5 W AC-3 - Ith 150 A
- Average Impedance
- 0.00018 Ohm
- Auxiliary Contact Composition
- 1 NO + 1 NC
- Connection Pitch
- 35 mm
- [Ith] Conventional Free Air Thermal Current
- 275 A (at 40 °C)
- Standards
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1
- Mounting Support
- plate
- Hold-In Power Consumption In W
- 5.7-5.7 W
- Rated Breaking Capacity
- 1280 A at 440 V
- Irms Rated Making Capacity
- 1890 A at 440 V
- Associated Fuse Rating
- 160 A aM at <= 440 V for motor || 160 A aM at <= 690 V for motor || 315 A gG at <= 690 V
- Net Weight
- 4.1 kg
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Inrush Power In Va
- 290-290 VA
- Pole Contact Composition
- 3 NO
- Connections - Terminals
- power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end || control circuit: push-in 2 0.5-1.0 mm² with cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
- Coil Technology
- built-in bidirectional peak limiting
- Operating Time
- 40...70 ms closing || 15...50 ms opening
- Maximum Operating Rate
- 600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
- Mechanical Durability
- 8 Mcycles
- Tightening Torque
- 18 N.m
- Compatibility Code
- LC1G
- Hold-In Power Consumption In Va
- 10-10 VA
- Width
- 108 mm
- Overvoltage Category
- III
- Depth
- 193 mm
- Maximum Horse Power Rating
- 40 hp at 200/208 V 60 Hz || 50 hp at 230/240 V 60 Hz || 100 hp at 460/480 V 60 Hz || 125 hp at 575/600 V 60 Hz
- Motor Power Kw
- 37 kW at 230 V AC 50/60 Hz (AC-3e) || 75 kW at 400 V AC 50/60 Hz (AC-3e) || 75 kW at 415 V AC 50/60 Hz (AC-3e) || 90 kW at 440 V AC 50/60 Hz (AC-3e) || 90 kW at 500 V AC 50/60 Hz (AC-3e) || 90 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC 50/60 Hz (AC-3e) || 37 kW at 230 V AC 50/60 Hz (AC-3) || 75 kW at 400 V AC 50/60 Hz (AC-3) || 75 kW at 415 V AC 50/60 Hz (AC-3) || 90 kW at 440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 90 kW at 690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 37 kW at 230 V AC 50/60 Hz (AC-4) || 75 kW at 400 V AC 50/60 Hz (AC-4) || 75 kW at 415 V AC 50/60 Hz (AC-4) || 80 kW at 440 V AC 50/60 Hz (AC-4) || 90 kW at 500 V AC 50/60 Hz (AC-4) || 90 kW at 690 V AC 50/60 Hz (AC-4) || 75 kW at 1000 V AC 50/60 Hz (AC-4)
- [Ui] Rated Insulation Voltage
- 1000 V
- Inrush Power In W
- 220 W
- [Icw] Rated Short-Time Withstand Current
- 1.2 kA - 10 s || 0.7 kA - 30 s || 0.6 kA - 1 min || 0.45 kA - 3 min || 0.35 kA - 10 min
Specifications
- [Uc] Control Circuit Voltage
- 24...48 V AC 50/60 Hz || 24...48 V DC
- [Ue] Rated Operational Voltage
- <= 1000 V AC 50/60 Hz || <= 460 V DC
- Range Of Product
- TeSys Giga
- Control Circuit Voltage Limits
- operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
- Contactor Application
- power switching || motor control
- Product Or Component Type
- contactor
- Range
- TeSys
- Utilisation Category
- AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
- [Ie] Rated Operational Current
- 275 A (at <40 °C) at <= 1000 V AC-1 || 150 A (at <60 °C) at <= 440 V AC-3
- Poles Description
- 3P
- Device Short Name
- LC1G
Environment
- Ambient Air Temperature For Operation
- -25-60 °C
- Ambient Air Temperature For Storage
- -60-80 °C
- Protective Treatment
- TH
- Ip Degree Of Protection
- IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
- Mechanical Robustness
- vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
- Color
- dark grey
- Permissible Ambient Air Temperature Around The Device
- -40-70 °C at Uc
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP2105013
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI2105013
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free plastic parts product
Documents
Data Sheet
DownloadCAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther