Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 400A, standard version, 200-500V AC/DC wide band coil
LC1G400LSEN
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Complementary

Product Certifications
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Height
225 mm
Power Dissipation Per Pole
30 W AC-1 - Ith 550 A || 16 W AC-3 - Ith 400 A
Average Impedance
0.0001 Ohm
Auxiliary Contact Composition
1 NO + 1 NC
Connection Pitch
45 mm
[Ith] Conventional Free Air Thermal Current
550 A (at 40 °C)
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1
Mounting Support
plate
Hold-In Power Consumption In W
8.6-8.6 W
Rated Breaking Capacity
3480 A at 440 V
Irms Rated Making Capacity
5090 A at 440 V
Associated Fuse Rating
500 A aM at <= 440 V for motor || 315 A aM at <= 690 V for motor || 630 A gG at <= 690 V
Net Weight
7.5 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
535-535 VA
Pole Contact Composition
3 NO
Connections - Terminals
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end || control circuit: push-in 2 0.5-1.0 mm² with cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology
built-in bidirectional peak limiting
Operating Time
40...70 ms closing || 15...50 ms opening
Maximum Operating Rate
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Mechanical Durability
8 Mcycles
Tightening Torque
35 N.m
Compatibility Code
LC1G
Hold-In Power Consumption In Va
15.4-15.4 VA
Width
140 mm
Overvoltage Category
III
Depth
226 mm
Motor Power Kw
110 kW at 230 V AC 50/60 Hz (AC-3e) || 200 kW at 400 V AC 50/60 Hz (AC-3e) || 200 kW at 415 V AC 50/60 Hz (AC-3e) || 250 kW at 440 V AC 50/60 Hz (AC-3e) || 250 kW at 500 V AC 50/60 Hz (AC-3e) || 315 kW at 690 V AC 50/60 Hz (AC-3e) || 220 kW at 1000 V AC 50/60 Hz (AC-3e) || 110 kW at 230 V AC 50/60 Hz (AC-3) || 200 kW at 400 V AC 50/60 Hz (AC-3) || 200 kW at 415 V AC 50/60 Hz (AC-3) || 250 kW at 440 V AC 50/60 Hz (AC-3) || 250 kW at 500 V AC 50/60 Hz (AC-3) || 315 kW at 690 V AC 50/60 Hz (AC-3) || 220 kW at 1000 V AC 50/60 Hz (AC-3) || 110 kW at 230 V AC 50/60 Hz (AC-4) || 200 kW at 400 V AC 50/60 Hz (AC-4) || 200 kW at 415 V AC 50/60 Hz (AC-4) || 220 kW at 440 V AC 50/60 Hz (AC-4) || 250 kW at 500 V AC 50/60 Hz (AC-4) || 315 kW at 690 V AC 50/60 Hz (AC-4) || 220 kW at 1000 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating
125 hp at 200/208 V 60 Hz || 150 hp at 230/240 V 60 Hz || 300 hp at 460/480 V 60 Hz || 400 hp at 575/600 V 60 Hz
[Ui] Rated Insulation Voltage
1000 V
Inrush Power In W
300 W
[Icw] Rated Short-Time Withstand Current
3.6 kA - 10 s || 2.4 kA - 30 s || 1.7 kA - 1 min || 1.2 kA - 3 min || 1.0 kA - 10 min

Environment

Ambient Air Temperature For Operation
-25-60 °C
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Mechanical Robustness
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Color
dark grey
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2105013
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI2105013
Eu Rohs Directive
Compliant with Exemptions

Specifications

[Uc] Control Circuit Voltage
200...500 V AC 50/60 Hz || 200...500 V DC
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz || <= 460 V DC
Range Of Product
TeSys Giga
Control Circuit Voltage Limits
operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Contactor Application
power switching || motor control
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
[Ie] Rated Operational Current
550 A (at <40 °C) at <= 1000 V AC-1 || 400 A (at <60 °C) at <= 440 V AC-3
Poles Description
3P