Schneider Electric

LR9D08KITD09BD

Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay
LR9D08KITD09BD
LR9D08KITD09BD
LR9D08KITD09BD
LR9D08KITD09BD
LR9D08KITD09BD
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Product Certifications
LROS (Lloyds register of shipping) || CSA || UL || GOST || DNV || CCC || GL || BV || RINA
[Uc] Control Circuit Voltage
24 V DC
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole
1.56 W AC-1 || 0.2 W AC-3
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
25 A (at 60 °C) for power circuit || 10 A (at 60 °C) for signalling circuit
Phase Failure Sensitivity
phase difference > 40% 3-3 s IEC 60947-4-1
Mounting Support
plate || rail
Control Circuit Type
DC standard
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
motor control || resistive load
Relay Application
motor protection
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type
motor starter
Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Connections - Terminals
power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid without cable end || power circuit screw clamp terminals 2 1-4 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end
Range
TeSys
Pole Contact Composition
3 NO
Utilisation Category
AC-4 || AC-1 || AC-3
Maximum Operating Rate
3600 cyc/h 60 °C
Tightening Torque
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Mechanical Durability
30 Mcycles
Poles Description
3P
Operating Time
53.55...72.45 ms closing || 16...24 ms opening
Overvoltage Category
III
Motor Power Kw
2.2 kW at 220...230 V AC 50/60 Hz (AC-3) || 4 kW at 380...400 V AC 50/60 Hz (AC-3) || 4 kW at 415...440 V AC 50/60 Hz (AC-3) || 5.5 kW at 500 V AC 50/60 Hz (AC-3) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 2.2 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Protective Cover
with

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
-5-60 °C
Height
77 mm
Standards
UL 60947-4-1 || IEC 60947-4-1 || GB 14048.4 || CSA C22.2
Ambient Air Temperature For Operation
-25-70 °C IEC 60255-8
Pollution Degree
3
Product Certifications
TÜV || CSA || cULus || CCC
Electromagnetic Compatibility
surge withstand 2 kV common mode IEC 61000-4-5 || resistance to electrostatic discharge 8 kV IEC 61000-4-2 || immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3 || immunity to fast transients 2 kV IEC 61000-4-4
Dielectric Strength
6 kV 50 Hz IEC 60255-5
Net Weight
0.48 kg
Depth
79.9 mm
Flame Retardance
V1 conforming to UL 94
Ambient Air Temperature For Storage
-60-80 °C
Width
45 mm
Height
72.5 mm
Protective Treatment
TH IEC 60068-2-30
Net Weight
0.18 kg
Ip Degree Of Protection
IP20 front face IEC 60529
Operating Altitude
6561.68 ft (2000 m) without derating
Operating Altitude
9842.52 ft (3000 m) without derating
Fire Resistance
850 °C IEC 60695-2-1
Depth
95 mm
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Complementary

Time Range
1.5...4 min - automatic reset time
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
[Ith] Conventional Free Air Thermal Current
5 A signalling circuit
Tightening Torque
control circuit 0.8 N.m screw clamp terminals || power circuit 3.1 N.m screw clamp terminals
Control Circuit Voltage Limits
drop-out 0.1...0.25 Uc DC 60 °C) || operational 0.7...1.25 Uc DC 60 °C)
[Ue] Rated Operational Voltage
690 V power circuit || 660 V signalling circuit
Contact Compatibility
M4
Thermal Protection Adjustment Range
0.4-2 A
Power Consumption In W
300 mW
Contactor Coil Voltage
24 V DC standard
Hold-In Power Consumption In W
5.4-5.4 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Ip Degree Of Protection
front face IP20 IEC 60529 || front face IP20 VDE 0106
Thermal Overload Class
class 5…30
Associated Fuse Rating
5 A gG signalling circuit || 5 A BS signalling circuit
Power Range
1.1-2 kW 200-240 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 4-6 kW 480-500 V 3 phase
[Uimp] Rated Impulse Withstand Voltage
6 kV
Connections - Terminals
control circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end || power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end
Coil Technology
built-in bidirectional peak limiting diode suppressor
Time Constant
28 ms
[Ui] Rated Insulation Voltage
power circuit 1000 V || signalling circuit 690 V
Motor Starter Type
direct on-line contactor
Minimum Switching Voltage
17 V for signalling circuit
Tripping Threshold
1.25 In IEC 60947-4-1
Signalling Circuit Frequency
25...400 Hz
Control Type
Red push-button stop and manual reset || White 2 microswitches adjustable trip class || Red knob automatic reset || White dial full-load current adjustment
Mounting Support
under contactor || plate, with specific accessories || rail, with specific accessories
Inrush Power In W
5.4-5.4 W 20 °C)
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mechanical Robustness
vibrations 10...150 Hz 6 Gn) IEC 60068-2-6 || shocks 11 ms 15 gn) IEC 60068-2-7

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1502001EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1502001EN
Eu Rohs Directive
Compliant with Exemptions

Documents

Data Sheet

Download

Related products