Additional Information
- Part Number
- LTMR100DFM
- UNSPSC
- 39122214
- Tariff Code
- 8537109160
- Country of Origin
- CN
Environment
- Product Certifications
- CSA || DNV || LROS (Lloyds register of shipping) || RINA || EAC || GL || UL || ATEX || BV || CCC || RMRoS || KERI || ABS || NOM || C-tick
- Mechanical Robustness
- vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
- Ambient Air Temperature For Operation
- -20-60 °C
- Standards
- EN 60947-4-1 || UL 508 || IEC 60947-4-1 || CSA C22.2 No 14 || IACS E10
- Ambient Air Temperature For Storage
- -40-80 °C
- Protective Treatment
- 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
- Operating Altitude
- <= 6561.68 ft (2000 m) without derating
- Fire Resistance
- 650 °C EN/IEC 60695-2-12 || 960 °C UL 94
- Ip Degree Of Protection
- IP20
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP060308EN_V2
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI100411EN_V2
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free plastic parts product
Complementary
- Contacts Type And Composition
- 1 NO + 1 NC fault signal || 3 NO
- Height
- 61 mm
- Connection Pitch
- 5.08 mm
- Permissible Power
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Network And Machine Diagnosis Type
- motor control command recording || trip history information || running hours counter/operating time || phase fault and earth fault trip counters || remaining operating time before overload tripping || fault recording || trip context information || event recording || starting current and time || waiting time after overload tripping
- Pollution Degree
- 3
- Logic Input Number
- 6
- Maximum Operating Rate
- 1800 cyc/h
- Connections - Terminals
- control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
- Input Current
- 3.1 mA 100 V || 7.5 mA 240 V
- Current State 1 Guaranteed
- logic input 79...264 V >= 2 mA 25 ms
- Net Weight
- 0.53 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
- Associated Fuse Rating
- 4 A gG output || 0.5 A gG control circuit
- Electromagnetic Compatibility
- electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
- Measurement Accuracy
- 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
- Current State 0 Guaranteed
- logic input 0...40 V <= 15 mA 25 ms
- [Ui] Rated Insulation Voltage
- 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
- Short-Circuit Withstand
- 100 kA conforming to EN/IEC 60947-4-1
- Compatibility Code
- LTMR
- Protection Type
- phase failure || overload (long time) || load fluctuation || thermal overload protection || power factor variation || overload || locked rotor || thermal protection || earth-leakage protection || phase unbalance || reverse polarity protection
- Web Services
- web server
- Width
- 91 mm
- Load Current
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Tightening Torque
- control circuit 0.5-0.6 N.m flat 3 mm
- Overvoltage Category
- III
- Depth
- 122.5 mm
- Maximum Operating Frequency
- 2 Hz
- Metering Type
- imbalance current || temperature || average current Iavg || earth-fault current || phase current I1, I2, I3 RMS
Specifications
- Product Or Component Type
- motor controller
- Product Name
- TeSys T
- Measurement Current
- 5-100 A
- Range
- TeSys
- Current Consumption
- 8...62.8 mA
- [Us] Rated Supply Voltage
- 100...240 V AC 50/60 Hz
- Communication Port Protocol
- DeviceNet
- Bus Type
- DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
- Supply Voltage Limits
- 93.5-264 V AC
- Device Application
- equipment monitoring and control
- Device Short Name
- LTMR
Documents
Data Sheet
DownloadCAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther