Schneider Electric
LV433492
Circuit breaker, ComPact NSX250HB2, 100kA/690VAC, TMD trip unit 250A, 3 poles 3d
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€1,037.21
Additional Information
- Part Number
- LV433492
- UNSPSC
- 39121601
- Country of Origin
- PL
Specifications
- Network Frequency
- 50/60 Hz
- Line Rated Current
- 250 A 40 °C
- Trip Unit Name
- TM-D
- Range Of Product
- ComPact NSX100...250
- [Ue] Rated Operational Voltage
- 690 V AC 50/60 Hz
- Trip Unit Protection Functions
- LI
- Network Type
- AC
- Protected Poles Description
- 3t
- Product Or Component Type
- circuit breaker
- Product Name
- ComPact NSX
- Range
- ComPact
- Control Type
- toggle
- Utilisation Category
- category A
- Mounting Mode
- fixed
- Breaking Capacity
- 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
- Suitability For Isolation
- yes EN/IEC 60947-2
- Poles Description
- 3P
- Breaking Capacity Code
- HB2 100 kA 690 V AC
- Device Application
- distribution
- Device Short Name
- NSX250HB2
- Trip Unit Technology
- thermal-magnetic
Contractual warranty
- Warranty
- 18 months
Complementary
- [Ics] Rated Service Breaking Capacity
- 100 kA 500 V AC 50/60 Hz IEC 60947-2 || 100 kA 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 660/690 V AC 50/60 Hz IEC 60947-2
- Height
- 161 mm
- Earth-Leakage Protection
- without
- Mounting Support
- backplate
- Downside Connection
- front
- Number Of Slots
- 5
- Protection Type
- L : for overload protection (thermal) || I : for short-circuit protection (magnetic)
- Long Time Delay Adjustment Type
- fixed
- Net Weight
- 2.4 kg
- [Tr] Long-Time Delay Adjustment Range
- 120-400 s 1.5 x In || 15-15 s 6 x Ir
- Electrical Durability
- 5000 cycles 690 V In || 10000 cycles 690 V In/2 || 10000 cycles 440 V In || 20000 cycles 440 V In/2
- Short-Time Delay Adjustment Type
- fixed
- Long Time Pick-Up Adjustment Type Ir
- adjustable
- Long Time Pick-Up Adjustment Range
- 0.7...1 x In
- Upside Connection
- front
- [Ui] Rated Insulation Voltage
- 800 V AC 50/60 Hz
- Trip Unit Rating
- 250-250 A 40 °C
- Mechanical Durability
- 20000 cycles
- [Isd] Short-Time Pick-Up Adjustment Range
- 5...10 x In
- Connection Pitch
- 35 mm
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Width
- 105 mm
- Depth
- 86 mm
- Short-Time Pick-Up Adjustment Type Isd
- adjustable
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP120606EN
- Sustainable Offer Status
- Green Premium product
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI120604EN
- Eu Rohs Directive
- Compliant
Environment
- Product Certifications
- Marine || EAC || CCC
- Ik Degree Of Protection
- IK07 IEC 62262
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/IEC 60947
- Ip Degree Of Protection
- IP40 conforming to IEC 60529
- Electrical Shock Protection Class
- class II
- Pollution Degree
- 3 IEC 60664-1
- Ambient Air Temperature For Storage
- -50-85 °C
- Relative Humidity
- 0-95 %
- Operating Altitude
- 0...6561.68 ft (0...2000 m) without derating || 2000 m...5000 m with derating
- Overvoltage Category
- class II
CAD Models
traceparts
Download