- Part Number
- LV847283
- UNSPSC
- 39121601
Specifications
- Network Frequency
- 50/60 Hz
- Trip Unit Protection Functions
- LSI
- Network Type
- AC
- [Ue] Rated Operational Voltage
- 690 V AC, +/- 10 %
- Range Compatibility
- MasterPact (MasterPact MTZ1) circuit breaker || MasterPact (MasterPact MTZ2) circuit breaker || MasterPact (MasterPact MTZ3) circuit breaker || MasterPact (MasterPact MTZ2 H10) circuit breaker
- Protected Poles Description
- 3P 3d || 4P 3d || 4P 3d + N/2 || 4P 4d || 4P 3d + OSN
- Trip Unit Rating
- 400-400 A || 630-630 A || 800-800 A || 1000-1000 A || 1250-1250 A || 1600-1600 A || 2000-2000 A || 2500-2500 A || 3200-3200 A || 4000-4000 A || 5000-5000 A || 6300-6300 A
- Product Or Component Type
- control unit
- Range
- MasterPact
- Circuit Breaker Application
- distribution IEC standard
- Poles Description
- 3P || 4P
- Protection Type
- overload protection (long time) ANSI 49 || instantaneous short-circuit protection ANSI 50 || short time short-circuit protection ANSI 51
- Device Application
- equipment protection, monitoring and control
- Device Short Name
- Micrologic 5.0 X
- Trip Unit Technology
- electronic
Contractual warranty
- Warranty
- 18 months
Complementary
- Measurement Voltage
- 145.6-828 V AC 50/60 Hz per phase
- Thermal Memory
- yes
- Frequency Measurement Range
- 45-250 Hz
- Type Of Measurement
- power meter
- Long Time Pick-Up Adjustment Range
- 0.4...1 x In adjustable in step of 1 A
- Communication Port Protocol
- Bluetooth 4.0 LE peer to peer 30 kbit/s || NFC peer to peer ISO 15963 || USB peer to peer 115 kbauds
- Display Type
- LCD display - 128 x 96 pixels
- Long Time Delay Adjustment Type
- adjustable in step of 0.5 s
- Instantaneous Pick-Up Adjustment Type Ii
- adjustable
- Zone Selective Interlocking Zsi
- with
- Metering Type
- current I1, I2, I3, In, Ig maximum standard) || average voltage Vavg standard) || active power P, P1, P2, P3 standard) || reactive power Q, Q1, Q2, Q3 standard) || apparent power S, S1, S2, S3 standard) || power factor standard) || frequency standard) || total current harmonic distortion THD (I) inst, avg, avg min, avg max fundamental voltage standard) || total current harmonic distortion THD (I) inst, avg, avg min, avg max RMS voltage standard) || voltage V21, V32, V13, V1, V2, V3 instantaneous standard) || voltage V21, V32, V13, V1, V2, V3 minimum standard) || voltage V21, V32, V13, V1, V2, V3 maximum standard) || total voltage harmonic distortion THD (V) inst, avg, avg min, avg max fundamental voltage standard) || total voltage harmonic distortion THD (V) inst, avg, avg min, avg max RMS voltage standard) || demand current I1, I2, I3, In, Iavg standard) || demand power P, Q, S standard)
- [Tr] Long-Time Delay Adjustment Range
- 12.5-600 s 1.5 x Ir || 0.5-24 s 6 x Ir || 0.7-16.6 s 7.2 x Ir
- Short-Time Delay Adjustment Type
- adjustable
- Neutral Protection Setting
- 1 x Ir || 0.5 x Ir || 1.6 x Ir || no protection
- Instantaneous Pick-Up Adjustment Range
- 2...15 x In adjustable in step of 0.5 x In embedded HMI || 2...15 x In adjustable in step of 0.1 x In Ecoreach software or MasterPact MTZ mobile app || Ii enable on/off
- Operating Time
- 0 ms fast || 20 ms standard
- Mounting Mode
- fixed
- [Tsd] Short-Time Delay Adjustment Range
- 0.1-0.4 s I²t=on || 0-0.4 s I²t=off
- Measurement Accuracy
- power factor +/- 1 % || active energy Ep IN/OUT/tot +/- 1 % - 10...10 GWh || reactive energy Ep IN/OUT/tot +/- 2 % - 10...10 GVARh || apparent energy Es IN/OUT/tot +/- 1 % - 10...10 GVAh || unbalance current +/- 0.5 % || frequency +/- 0.005 Hz || voltage V21, V32, V13, VLLavg +/- 0.5 % 208...690 x 1.2 V || voltage V21, V32, V13, VLNavg +/- 0.5 % 120...400 x 1.2 V || apparent power S, S1, S2, S3, Sdemand +/- 1 % || active power P, P1, P2, P3, Pdemand +/- 1 % || reactive power Q, Q1, Q2, Q3, Qdemand +/- 2 % || current I1, I2, I3, Iavg, Idemand for MTZ1 +/- 0.5 % 40...1600 x 1.2 A || current I1, I2, I3, Iavg, Idemand for MTZ2 +/- 0.5 % 40...4000 x 1.2 A || current I1, I2, I3, Iavg, Idemand for MTZ3 +/- 0.5 % 80...6300 x 1.2 A
- Data Recording
- data logs || time stamping || alarm logs || min/max of instantaneous values || event logs || maintenance logs
- Network And Machine Diagnosis Type
- system (HMI) health state overview circuit breaker health state standard) || contacts state circuit breaker health state standard) || micrologic service life circuit breaker health state standard) || tripping cause indication circuit breaker tripping cause standard) || identification card diagnostic data standard) || configured alarms synthesis diagnostic data standard) || monitored function diagnostic data standard) || operation diagnostic data standard) || micrologic test test standard) || protection test test standard) || selectivity test test standard) || trip context information crisis management standard) || operation advanced diagnostic standard) || breaker service life circuit breaker health state standard)
- Energy Management
- measurement ,active, reactive and apparent energy (standard) || measurement ,electrical network (standard) || measurement ,energy (standard)
- [Isd] Short-Time Pick-Up Adjustment Range
- 1.5...10 x Ir adjustable in step of 0.5 x Ir embedded HMI || 1.5...10 x Ir adjustable in step of 0.1 x Ir Ecoreach software or MasterPact MTZ mobile app
- Accuracy Class
- class 5 total current harmonic distortion THD (I) || class 0.5 unbalance voltage || class 1 active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) || class 2 total voltage harmonic distortion THD (V)
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1607009EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI1607009EN
- Eu Rohs Directive
- Compliant
- Halogen Content Performance
- Halogen free plastic parts product
Environment
- Standards
- EN/IEC 60947-1 || EN/IEC 60092-202 || EN/IEC 60947-2 || EN/IEC 60255-1 || EN/IEC 61010-1
- Ambient Air Temperature For Operation
- -25-70 °C operating) || -35--35 °C for start-up of product)
- Electromagnetic Compatibility
- electrostatic discharge immunity test IEC 61000-4-2 || susceptibility to electromagnetic fields IEC 61000-4-3 || electrical fast transient/burst immunity test IEC 61000-4-4 || 1.2/50 µs shock waves immunity test IEC 61000-4-5 || conducted RF disturbances IEC 61000-4-6 || conducted and radiated emissionsA CISPR 22
- Environmental Characteristic
- wet location not approved for use IEC 61010-1
- Mounting Location
- indoor use only
- Pollution Degree
- 3 IEC 60947-1
- Overvoltage Category
- IV IEC 61010-1
- Relative Humidity
- 95-95 % 55-55 °C IEC 60068-2-30
- Operating Altitude
- <= 6561.68 ft (2000 m) without derating || <= 13123.36 ft (4000 m) with operational voltage derating 600 V AC || <= 16404.2 ft (5000 m) with operational voltage derating 560 V AC
- Measurement Category
- category IV IEC 61010-2-30