Specifications

[Uc] Control Circuit Voltage
200...500 V AC/DC 50/60 Hz
Range Compatibility
TeSys G LX1G contactor coil
Product Or Component Type
contactor coil
Range
TeSys
Maximum Operating Rate
600 cyc/mn 60 °C
Poles Description
3P
Operating Time
20...35 ms opening || 40...55 ms closing
Product Compatibility
LC1G400...500
Device Short Name
LX1G
Mechanical Durability
5 Mcycles

Environment

Ambient Air Temperature For Operation
-25-60 °C
Height
167.0 mm
Standards
EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
Electromagnetic Compatibility
EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity test conforming to SEMI F47
Ip Degree Of Protection
IP20 IEC 60529
Pollution Degree
3 IEC 60947-1
Ambient Air Temperature For Storage
-60-80 °C
Operating Altitude
9842.52 ft (3000 m) without derating || 5000 m with derating factor
Quantity Per Set
1
Width
140.0 mm
Depth
93.0 mm
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2105013
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI2105013
Eu Rohs Directive
Compliant with Exemptions

Complementary

Control Circuit Voltage Limits
operational 0.8...1.1 Uc 60 °C) || drop-out 0...0.45 Uc 60 °C)
Hold-In Power Consumption In W
8.6-8.6 W
Inrush Power In Va
535-535 VA
Connections - Terminals
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2 0.5-1.0 mm² rigid or stranded with cable end sleeve AWG 20...AWG 18
Coil Technology
built-in bidirectional peak limiting
Hold-In Power Consumption In Va
15.4-15.4 VA
Inrush Power In W
300 W