Miniature circuit breaker (MCB), Multi9 C60H-DC, 2P, 32A, C curve, 5kA (UL1077), 6kA (IEC/EN 60947-2)
M9U21232
M9U21232
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€23.40
1
Payment methods:
A total of 1 Part In-Stock from 12 Distributors

Additional Information

Part Number
M9U21232
UNSPSC
39121603
Tariff Code
8536200020
Country of Origin
CN

Environment

Ambient Air Temperature For Operation
-25-70 °C
Tropicalisation
2 IEC 60068-2 || 2 GB 14048.2
Ip Degree Of Protection
IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree
3 EN/IEC 60947-2
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
95-95 % 55-55 °C
Heat Dissipation
7-7 W 440 V - 32 A

Complementary

[Ics] Rated Service Breaking Capacity
7.5 kA 75 % EN/IEC 60947-2 - 440 V DC || 4.5 kA 75 % EN/IEC 60947-2 - 500 V DC || 15 kA 75 % EN/IEC 60947-2 - 220 V DC || 7.5 kA 75 % GB 14048.2 - 440 V DC || 4.5 kA 75 % GB 14048.2 - 500 V DC || 15 kA 75 % GB 14048.2 - 220 V DC
Height
81 mm
Contact Position Indicator
yes
Earth-Leakage Protection
without
Mounting Support
DIN rail
9 Mm Pitches
4
Net Weight
0.128 kg
Wire Stripping Length
14 mm for top or bottom connection
Control Type
toggle
Connections - Terminals
tunnel type terminal top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid stranded || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 4) - flexible || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 4) - flexible with ferrule || tunnel type terminal top or bottom) - 2 1-16 mm² AWG 18...AWG 6) - rigid stranded || tunnel type terminal top or bottom) - 2 1-16 mm² AWG 18...AWG 6) - flexible || tunnel type terminal top or bottom) - 2 1-16 mm² AWG 18...AWG 6) - flexible with ferrule || tunnel type terminal top or bottom) - 3 4-4 mm² AWG 6) - flexible stranded
[Ui] Rated Insulation Voltage
500 V DC EN/IEC 60947-2
Mounting Mode
clip-on
Electrical Durability
3000 cycles 250 V DC L/R = 2 ms || 6000 cycles 250 V DC
Mechanical Durability
20000 cycles
Local Signalling
ON/OFF indication
[Uimp] Rated Impulse Withstand Voltage
6 kVEN/IEC 60947-2
Color
Gray
Width
36 mm
Provision For Padlocking
padlockable
Depth
73 mm
Tightening Torque
3.5-3.5 N.m top or bottom
Magnetic Tripping Limit
7...10 x In DC
[Ue] Rated Operational Voltage
220 V DC || 440 V DC || 500 V DC

Specifications

Line Rated Current
32 A 25 °C EN/IEC 60947-2
Curve Code
C
Number Of Protected Poles
2
Network Type
DC
Standards
EN/IEC 60947-2 || GB 14048.2 || UL 1077
Product Certifications
IEC || CCC || UR
Product Or Component Type
miniature circuit-breaker
Product Name
Multi9 C60H-DC
Utilisation Category
category A EN/IEC 60947-2
Range
Multi9
Breaking Capacity
20 kA Icu 220 V DC EN/IEC 60947-2 || 10 kA Icu 440 V DC EN/IEC 60947-2 || 6 kA Icu 500 V DC EN/IEC 60947-2 || 5 kA AIR 12...500 V DC UL 1077 || 20 kA Icu 220 V DC GB 14048.2 || 10 kA Icu 440 V DC GB 14048.2 || 6 kA Icu 500 V DC GB 14048.2
Suitability For Isolation
yes EN/IEC 60947-2
Poles Description
2P
Device Application
distribution
Device Short Name
C60H-DC
Trip Unit Technology
thermal-magnetic

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2308050EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A
Eu Rohs Directive
Compliant

Documents

Data Sheet

Download

Related products