Part Number
METSEEM4904E
UNSPSC
83101808
Tariff Code
9028300000
Country of Origin
CA

Environment

Ambient Air Temperature For Operation
0-60 °C
Height
70 mm
Standards
UL 508 || IEC 61010
Net Weight
1.5 kg
Pollution Degree
2
Mounting Mode
wall mount
Ambient Air Temperature For Storage
-40-70 °C
Width
253 mm
Depth
307 mm
Installation Category
III

Specifications

Network Frequency
60 Hz || 50 Hz
Type Of Measurement
current per phase, rms || current average || phase angle || active power total || active power per phase || apparent power total || apparent power per phase || power factor average || power factor per phase || active energy
Power Monitoring
basic instrumentation
Product Or Component Type
multi-circuit energy meter
Product Name
PowerLogic EM4900E
Range
PowerLogic
Energy Management
sub billing and cost allocation || billing analysis
[Us] Rated Supply Voltage
100...277 V AC 50/60 Hz
Device Application
sub billing
Device Short Name
EM4904
Metering Type
demand power P || demand current I1, I2, I3, peak demand current IM1, IM2, IM3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs Directive
Compliant with Exemptions

Complementary

Communication Port Support
spring connector RS485 || RJ45
Measurement Voltage
150-480 V AC 50/60 Hz between phases || 90-277 V AC 50/60 Hz between phase and neutral
Sampling Rate
256 samples/cycle
Communication Port Protocol
Modbus RTU 9600, 19200, 38400 bps even/odd or none - 2 wires || Modbus TCP 9600, 19200, 38400 bps even/odd or none - 2 wires || SNMP || BACnet IP 10, 100 Mbits || BACnet MS/TP
Communication Service
updating firmware
Communication Of Data
high-high current alarm || under voltage alarm || high current alarm || low current alarm || total energy || over voltage alarm || low-low current alarm
Measurement Accuracy
power +/- 0.5 % of the measuring range || energy +/- 0.5 % of the measuring range || current +/- 0.5 % of the measuring range || voltage +/- 0.5 % of the measuring range
Refresh Time
2 s Modbus) || 14 s BACnet) || 20 s SNMP)
Data Recording
maximum of demand active power || maximum of instantaneous current || maximum of demand current
Analogue Input Type
solid core CT 0.333 V12 x single pole || solid core CT 0.333 V6 x single phase || solid core CT 0.333 V4 x three phase || split core CT 0.333 V12 x single pole || split core CT 0.333 V6 x single phase || split core CT 0.333 V4 x three phase
Web Services