Power quality meter, PowerLogic PM8000, Essential, transducer, 64MB, 128s/c
METSEPM8113
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Complementary

Communication Network Type
IPv6 (internet protocol)
Network Frequency
60 Hz || 50 Hz
Communication Port Support
ETHERNET || screw terminal block RS485
Power Quality Analysis
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring
Height
90.5 mm
Measurement Voltage
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Sampling Rate
128 samples/cycle
Standards
IEC 62053-24 || IEC 62052-11 || IEC 61557-12 || IEC 62053-22 || IEEE 1588 || IEC 62586-2 || IEC 61326-1
Memory Capacity
64 MB
Number Of Outputs
1 pulse
Product Certifications
CE || cULus || N998
Type Of Measurement
current || voltage total || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms
Communication Port Protocol
Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004
Power Consumption In W
17 W
Frequency Measurement Range
42-69 Hz
Communication Service
DHCP || SNMP || SMTP e-mail notification || RSTP support || NTP time synchronization || PTP time synchronization
Number Of Inputs
3 digital 30 V AC || 3 digital 60 V DC
Net Weight
528 g
Depth
90.8 mm
Measurement Current
50-10000 mA
Information Displayed
voltage || current || frequency || power || energy consumption || harmonic distortion
[Us] Rated Supply Voltage
20...60 V DC +/- 10 %
Mounting Mode
clip-on
Measurement Accuracy
current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
Mounting Support
DIN rail
Poles Description
3P || 1P + N || 3P + N
Data Recording
event logs || min/max of instantaneous values || time stamping || GPS synchronisation || alarm logs || data logs || trending/forecasting || sag and swell logs || waveform logs || sequence of event recording || harmonics logs || 10 data recorders
Line Rated Current
1 A || 10 A || 5 A
Cybersecurity
robust security logs || Syslog protocol support || password protection || port hardening || enable/disable communication ports
Isolation Voltage
III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
Web Services
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Width
90.5 mm
Display Type
Without Display
Device Application
WAGES metering || power monitoring
Accuracy Class
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12
Installation Category
III

Offer Sustainability

Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Compliant with Exemptions

Environment

Ambient Air Temperature For Operation
-25-70 °C
Electromagnetic Compatibility
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55022 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions conforming to FCC part 15 || conducted and radiated emissions conforming to ICES-003 || conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 || surge withstand (2...150 Hz) conforming to IEEE C37.90.1
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 %
Ip Degree Of Protection
IP30 IEC 60529
Operating Altitude
9842.52 ft (3000 m)

Specifications

Product Or Component Type
power meter
Product Name
PowerLogic PM8000
Range
PowerLogic
Device Short Name
PM8113

Documents

Data Sheet

Download

Related products