Sign-Up

Environment

Ambient Air Temperature For Operation
-2-70 °C
Standards
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Certifications
UL || CSA || NOM
Ip Degree Of Protection
front cover IP40
Pollution Degree
3 IEC 60947-1
Ambient Air Temperature For Storage
-50-85 °C
Quality Labels
CE
Operating Altitude
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407012EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1407012EN
Eu Rohs Directive
Compliant

Complementary

Mounting Mode
unit mount lug)
Network Frequency
50/60 Hz
Terminal Identifier
AL1200P25K
[Ics] Rated Service Breaking Capacity
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology
electronic, basic, ET 1.0I, I
Trip Unit Name
ET 1.0I
Height
16.16 in
[Ue] Rated Operational Voltage
480 V AC 50/60 Hz UL 489
Tightening Torque
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mounting Support
lug
Breaking Capacity Code
L
Local Signalling
1 trip indicator green)
Number Of Slots
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connection
lugs, line || lugs, load
Net Weight
32 lb(US)
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Circuit Breaker Application
HACR rated
Wire Stripping Length
30 mm
Line Rated Current
1000-1000 A
Long Time Pick-Up Adjustment Range
1 In
Continuous Current Rating
80 %
Breaking Capacity
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage
750 V IEC 60947-2
Poles Description
3P
Quantity Per Set
1
Awg Gauge
4 x AWG 3/0...500 kcmil aluminium/copper
Width
8.27 in
Depth
8.05 in

Specifications

Product Or Component Type
circuit breaker
Product Name
PowerPact P
Range
PowerPact
Device Application
distribution

Documents

Data Sheet

Download

Related products