Analogue Output Number
0
Input Type
6 1/5 A CT phase current || 2 5/1 A CT residual current || 1 1/0.2 A CT residual current || 4 100 V/110 V VT voltage
Range Of Product
PowerLogic P3
Connections - Terminals
screw removable (digital input/output) || ring lugs fixed (current transformer) || pin removable (voltage transformer)
Network And Machine Diagnosis Type
event recording || disturbance recording || tripping context
Device Mounting
flush
Number Of Outputs
10 DO || 1 watchdog
Protection Type
distance relay 21 || underimpedance 21G || overfluxing (V/Hz) 24 || synchro-check 25 || undervoltage 27 || positive sequence undervoltage 27P || directional active underpower 37P || field loss (underimpedance) 40 || negative sequence overcurrent 46 || thermal overload protection 49 || earth fault overcurrent 50N/51N || phase overcurrent 50/51 || breaker failure 50BF || switch ON to fault (SOTF) || capacitor bank unbalance 51C || voltage-restrained overcurrent 51V || overvoltage 59 || earth fault overvoltage 59N || restricted earth fault 64REF || stator earth fault 64S || directional phase overcurrent 67 || directional earth fault 67N || H2 detection 68H2 || H5 detection 68H5 || pole slip 78PS || underfrequency 81/81N || rate of change of frequency 81R || lockout relay 86 || machine differential 87M || programmable stages 99 || programmable curve || cold load pick-up
Relay Application
generator
Communication Port Protocol
IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet/IP || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus
Product Or Component Type
protection relay
Single Line Diagram
3 controlled + 5 displayed
Monitoring Function
trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring
Analogue Input Number
0
Relay Type
differential current relay
Control Type
switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I/O keys || local/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server
Digital Input Number
6
Setting
4
Integrated Connection Type
front USB port 1 || rear RJ45 1 || rear RS485 1
Cybersecurity
password protection || port hardening
Number Of Sensors
0 temperature sensor(s) || 0 arc sensor(s)
Switchgear Diagnosis Type
CT/VT supervision || trip circuit supervision TCS
Arc Flash Protection
yes
Type Of Measurement
current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption
Device Short Name
P3G32-CBG1A-DA1FA-BBAAB
[Us] Rated Supply Voltage
48...230 V AC/DC

Environment

Mechanical Robustness
vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3
Ambient Air Temperature For Operation
-40-65 °C
Environmental Characteristic
exposure to dry heat Bd EN/IEC 60068-2-2 || exposure to cold Ad EN/IEC 60068-2-1 || exposure to damp heat in service Db EN/IEC 60068-2-30 || exposure to damp heat in service Cab EN/IEC 60068-2-78
Ip Degree Of Protection
IP54 IEC 60529
Electromagnetic Compatibility
emission tests IEC/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC/EN 60255-26 ed. 3 || EMC immunity EN/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN/IEC 61000-4-8 || EMC immunity level 5 EN/IEC 61000-4-9 || EMC immunity EN/IEC 61000-4-29 || EMC immunity EN/IEC 61000-4-11 || EMC immunity EN/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN/IEC 60255-1
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
0-95 %, without condensation
Protective Treatment
conformal coating
Operating Altitude
6561.68 ft (2000 m)

Complementary

Number Of Key
2 customizable
Local Signalling
2 LEDs || 16 LEDs programmable
Depth
230 mm
Operating Threshold
110 V AC/DC
Time Synchronisation Protocol
SNTP
Width
270 mm
Height
176 mm
Display Type
LCD 128 x 128 pixels with single line diagram || LCD 128 x 128 pixels with ANSI symbols
Net Weight
4.2 kg maximum
Web Server
embedded HTTP server