Schneider Electric

XALD111H29H7

Complete control station, Harmony XALD, dark grey, 1 red flush pushbutton, 22mm, spring return, 1NO, marked STOP
XALD111H29H7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Environment

Product Certifications
CSA || UL Listed
Ik Degree Of Protection
IK03 IEC 62262
Ambient Air Temperature For Operation
-40-70 °C
Standards
IEC 60947-5-4 || JIS C8201-5-1 || IEC 60947-5-1 || IEC 60947-1 || IEC 60947-5-5 || UL 508 || CSA C22.2 No 14 || JIS C8201-1
Shock Resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance
5 gn 12-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529 || IP67 || IP69 || IP69K
Ambient Air Temperature For Storage
-40-70 °C
Overvoltage Category
class II IEC 60536
Nema Degree Of Protection
NEMA 13 || NEMA 4X
Protective Treatment
TH

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1806010EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1806010EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Operating Force
3.5 N NC changing electrical state
Short-Circuit Protection
10 A cartridge fuse gG IEC 60947-5-1
Operating Travel
1.5 mm NC changing electrical state) || 4.3 mm total travel)
Contacts Material
silver alloy (Ag/Ni)
Positive Opening
with IEC 60947-5-1 appendix K
[Ith] Conventional Free Air Thermal Current
10 A IEC 60947-5-1
Cable Entry
1 knock-out for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
Net Weight
0.157 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-1
Resistance To High Pressure Washer
7000000 Pa 55 °C 0.1 m
Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Connections - Terminals
screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
[Ui] Rated Insulation Voltage
600 V 3)IEC 60947-1
[Ie] Rated Operational Current
6 A 120 V, AC-15, A600 IEC 60947-5-1 || 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
Mechanical Durability
5000000 cycles
Electrical Reliability
λ < 10exp(-6) 5 V 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA IEC 60947-5-4
Tightening Torque
0.8-1.2 N.m IEC 60947-1
Shape Of Screw Head
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm

Specifications

Control Station Application
stop function
Product Destination
for XB5 Ø 22 mm control and signalling units
Range Of Product
Harmony XALD
Colour Of Base Of Enclosure
light grey RAL 7035)
Control Station Composition
1 flush push-button, red 1 NC STOP
Operators Description
red ''STOP'' 1 NC
Product Or Component Type
complete control station
Material
polycarbonate
Marking Location
marking on legend holder
Operator Profile
1 flush push-button
Colour Of Cover
dark grey RAL 7016)
Contact Operation
slow-break
Device Short Name
XALD

Documents

Data Sheet

Download

Related products