Schneider Electric

XCKMR44D2H29

Limit switch, Limit switches XC Standard, XCKMR, reverse head stay put crossed rods, 2x(NC+NO), slow, M20
XCKMR44D2H29
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
Send request for price

Additional Information

Part Number
XCKMR44D2H29
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
ID

Specifications

Type Of Approach
lateral approach, 2 directions
Series Name
special format
Contacts Type And Composition
2 x (1 NC + 1 NO)
Movement Of Operating Head
rotary
Body Type
fixed
Range Of Product
OsiSense XC
Contact Operation
slow-break, break before make
Product Specific Application
for hoisting and mechanical handling applications
Fixing Mode
by the body
Type Of Operator
stay put crossed rods lever metal square rod 6 mm, L = 200 mm
Body Material
zamak
Cable Entry
3 entries tapped for M20 x 1.5 cable gland 7-13 mm
Product Or Component Type
limit switch
Head Material
zamak
Material
metal
Device Short Name
XCKMR
Number Of Poles
4
Head Type
reversed rotary head

Contractual warranty

Warranty
18 months

Complementary

Switch Actuation
by any moving part
Maximum Displacement Angle
-180 ° || 180 °
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Height
118-118 mm
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Short-Circuit Protection
10 A cartridge fuse gG
Positive Opening
without
Minimum Actuation Speed
6 m/min
Contacts Insulation Form
Zb
Contact Block Per Direction [Control Circuit]
2 per direction
Electrical Connection
screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Mechanical Durability
2000000 cycles
Maximum Actuation Speed
1.5 m/s actuation point on the rod between 65 and 95 mm
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q150, DC-13 (Ue = 125 V), Ie = 0.55 A EN/IEC 60947-5-1 appendix A
Width
200 mm
Depth
59 mm
Minimum Torque For Tripping
0.5 N.m
Number Of Steps
4 electrical positions
Net Weight
0.55 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Eu Rohs Directive
Not applicable, out of EU RoHS legal scope
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CCC || CSA || CE || UL
Ik Degree Of Protection
IK07 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-85 °C
Standards
UL 508 || CSA C22.2 No 14 || EN/IEC 60947-5-1
Electrical Shock Protection Class
class I IEC 60536
Shock Resistance
50 gn EN/IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529

Documents

Data Sheet

Download

Related products