Limit switch, Limit switches XC Standard, XCPR, steel roller plunger, 1NC+1 NO, snap, Pg13
XCPR2102G13
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
Send request for price

Additional Information

Part Number
XCPR2102G13
UNSPSC
39122213
Country of Origin
FR

Specifications

Type Of Approach
lateral approach, 2 directions
Series Name
standard format
Reset
with
Contacts Type And Composition
1 NC + 1 NO
Movement Of Operating Head
linear
Body Type
fixed
Range Of Product
Telemecanique Limit switches XC Standard
Contact Operation
snap action
Fixing Mode
by the body
Type Of Operator
spring return roller plunger metal
Sensor Design
compact
Body Material
plastic
Cable Entry
1 entry tapped for Pg 13.5 cable gland 9-12 mm
Product Or Component Type
limit switch
Head Material
zamak
Material
plastic
Device Short Name
XCPR
Number Of Poles
2
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)EN 60947-1 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Height
65-65 mm
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Short-Circuit Protection
10 A cartridge fuse gG
Electrical Durability
5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
36 N
Positive Opening
with
Contacts Insulation Form
Zb
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Maximum Actuation Speed
0.5 m/s
Minimum Force For Tripping
12 N
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width
31 mm
Depth
30 mm
Net Weight
0.115 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Repeat Accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Circularity Profile
ENVEOLI110603EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || UL
Ik Degree Of Protection
IK04 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Overvoltage Category
class II IEC 61140 || class II NF C 20-030
Standards
EN 60204-1 || UL 508 || IEC 60204-1 || IEC 60947-5-1 || CSA C22.2 No 14 || EN 60947-5-1
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529

Documents

Data Sheet

Download

Related products