Safety limit switch, Telemecanique Safety switches XCS, metal, steel plunger, 2NC+1 NO, 1 entry tapped 1/2" NPT
XCSD3710N12
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Specifications

Contacts Type And Composition
1 NC + 1 NC + 1 NO
Type Of Approach
on end approach
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped 1/2" NPT
Contact Operation
slow-break, break before make
Type Of Operator
metal end plunger
Product Or Component Type
safety limit switch
Protection Technology
plastic protective cover, secured by 5-lobe socket head safety screw
Component Name
XCSD
Material
metal
Design
compact
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

Height
89-89 mm
[Ui] Rated Insulation Voltage
300 VUL 508 || 400 V 3)EN/IEC 60947-1 || 300 VCSA C22.2 No 14
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Positive Opening Minimum Force
45 N
Positive Opening
with NC contact
Minimum Actuation Speed
0.01 m/s
Clamping Connection Capacity
1 x 0.34...2 x 0.75 mm²
Repeat Accuracy
0.1 mm on tripping points, 1 million operating cycles for head with end plunger
Mechanical Durability
15000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Electrical Connection
terminal
[Ithe] Conventional Enclosed Thermal Current
6 A
Enclosure Material
Plastic
Minimum Force For Tripping
15 N
Contact Code Designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Width
34 mm
Depth
35 mm
Head Material
zamak
Net Weight
0.215 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 || 4 kV IEC 60664
Number Of Poles
3
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL || CSA
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN 1088/ISO 14119 || CSA C22.2 No 14 || UL 508 || EN/IEC 60204-1 || EN/IEC 60947-5-1
Electrical Shock Protection Class
class I NF C 20-030 || class I EN/IEC 61140
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508

Documents

Data Sheet