Additional Information

Part Number
XCSD3918N12
UNSPSC
39122213
Tariff Code
8536509065
Country of Origin
FR

Specifications

Contacts Type And Composition
1 NC + 1 NC + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped 1/2" NPT
Product Or Component Type
safety limit switch
Protection Technology
plastic protective cover, secured by 5-lobe socket head safety screw
Component Name
XCSD
Design
compact
Material
metal
Head Type
rotary head
Contact Operation
snap action
Type Of Operator
thermoplastic roller lever

Contractual warranty

Warranty
18 months

Complementary

Height
122-122 mm
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Clamping Connection Capacity
1 x 0.34...2 x 0.75 mm²
Repeat Accuracy
0.1 mm on tripping points, 1 million operating cycles for head with end plunger
[Ithe] Conventional Enclosed Thermal Current
6 A
Head Material
zamak
Net Weight
0.255 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 || 4 kV IEC 60664
Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 400 V 3)EN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening
with NC contact
Positive Opening Minimum Torque
0.25 N.m
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
1.5 m/s
Body Material
zamak
Electrical Connection
terminal
Enclosure Material
Plastic
Contact Code Designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Width
34 mm
Depth
35 mm
Minimum Torque For Tripping
0.1 N.m
Number Of Poles
3
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60204-1 || EN/IEC 60947-5-1 || UL 508 || EN 1088/ISO 14119 || CSA C22.2 No 14
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I NF C 20-030 || class I EN/IEC 61140
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective Treatment
TC
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508