Safety switch, Telemecanique Safety switches XCS, metal XCSE, 2NC + 1 NO, slow break, 2 entries tapped Pg 13, 24 V
XCSE7411
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 10 Parts In-Stock from 9 Distributors
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
Send request for price

Additional Information

Part Number
XCSE7411
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
FR

Specifications

[Us] Rated Supply Voltage
24 V - 20...10 %
Contacts Type And Composition
2 NC + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
2 entries tapped Pg 13.5
Electrical Connection
terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Description
with interlocking, locking by solenoid
Contact Operation
slow-break, break before make
Local Signalling
for guard open/guard closed and locked 2 LEDs (green or orange)
Solenoid Contacts Type And Composition
1 NC + 1 NO slow-break, simultaneous)
Electromagnet Interlocking
by mushroom head push-button turn to release for escape release || locking on de-energisation and unlocking on energisation of solenoid
Product Or Component Type
safety switch
Signalling Circuit Voltage
24/48 V 20...52 V)
Component Name
XCSE
Cable Outer Diameter
9-12 mm
Material
metal
Design
rectangular
Number Of Poles
3
Head Type
key operated turret head

Contractual warranty

Warranty
18 months

Complementary

Height
146-146 mm
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
50 VEN/IEC 60947-1 signalling circuit
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Positive Opening
with NC contact
Load Factor
1
Minimum Actuation Speed
0.01 m/s
[Ie] Rated Operational Current
0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Signalling Circuit Consumption
7 mA
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
[Ithe] Conventional Enclosed Thermal Current
6 A
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Power Consumption In Va
10 VA inrush || 10 VA sealed
Supply Voltage Type
AC/DC
Width
98 mm
Actuator Forcible Withdrawal Rtc
2000 N
Depth
44 mm
Head Material
zamak
Signalling Circuit Type
AC/DC
Protection Type
overvoltage protection signalling circuit
Net Weight
1.14 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Supply Frequency
50/60 Hz
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Circularity Profile
ENVEOLI110903EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110916EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation
-25-40 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60947-5-1 || EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/ISO 12100
Electrical Shock Protection Class
class I EN/IEC 61140
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1