Specifications

Range Of Product
Telemecanique Safety switches XCS
Electrical Connection
pre-cabled
Locking Options Description
without locking of actuator
Product Or Component Type
safety switch
Component Name
XCSMP
Design
miniature
Material
plastic
Head Type
key operated fixed head
Contacts Type And Composition
2 NC + 1 NO
Contact Operation
slow-break, break before make
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Height
87-87 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.05 m/s
Cable Length
5 m
[Ithe] Conventional Enclosed Thermal Current
2.5 A
Head Material
PA (polyamide)
Net Weight
0.11 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
20 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Insulation
double insulated
[Ie] Rated Operational Current
0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1 || 1.5 A 120 V, AC-15, C300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
8 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
1.5 m/s
Body Material
PA (polyamide)
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Cable Composition
6 x 0.5 mm²
Width
15 mm
Actuator Forcible Withdrawal Rtc
8 N
Depth
30 mm
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || cUL
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/ISO 12100 || CSA C22.2 No 14 || EN 1088/ISO 14119 || EN/IEC 60947-5-1 || UL 508 || EN/IEC 60204-1
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
6 gn 10-55 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-25-80 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Protective Treatment
TC