XMLA300E2S12
UNSPSC
39122210

Specifications

Contacts Type And Composition
1 C/O
Pressure Sensor Type
electromechanical pressure sensor
Pressure Sensor Size
300 bar
Pressure Actuator
piston
Electrical Connection
screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Controlled Fluid
fresh water 0-160 °C)
Awg Gauge
AWG 20...AWG 14
Range Of Product
OsiSense XM
Line Rated Current
3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Scale Type
fixed differential
Pressure Switch Type Of Operation
detection of 1 single threshold
Cable Entry
cable gland 7-13 mm
Electrical Circuit Type
control circuit
Enclosure Material
zinc alloy
Adjustable Range Of Switching Point On Rising Pressure
20-300 bar
Product Or Component Type
electromechanical pressure sensor
Adjustable Range Of Switching Point On Falling Pressure
3.5-265 bar
Maximum Permissible Accidental Pressure
675 bar
Materials In Contact With Fluid
FPM, FKM || PTFE || 316L stainless steel || brass
Destruction Pressure
1350 bar
Local Display
with
Device Short Name
XMLA
Fluid Connection Type
G 1/4 (female) ISO 228

Contractual warranty

Warranty
18 months

Complementary

Repeat Accuracy
2 %
Height
113 mm
Maximum Operating Rate
60 cyc/mn
Terminal Block Type
4 terminals
[Ui] Rated Insulation Voltage
300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Natural Differential At High Setting
35 bar +/- 6 bar)
Setting
external
Contacts Material
silver contacts
Mechanical Durability
3000000 cycles
Auxiliary Contacts Operation
snap action
Width
35 mm
Depth
75 mm
Net Weight
0.75 kg
Natural Differential At Low Setting
16.5 bar +/- 3 bar)
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A
Maximum Permissible Pressure - Per Cycle
375 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110914EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || UL || EAC || CCC || BV || LROS (Lloyds register of shipping)
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
UL 508 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || CE || EN 60947-5-1 || IEC 60947-5-1
Protective Treatment
TC standard version
Electrical Shock Protection Class
class I IEC 1140 || class I IEC 536 || class I NF C 20-030
Operating Position
any position
Vibration Resistance
4 gn 30-500 Hz)IEC 60068-2-6
Shock Resistance
50 gn IEC 60068-2-27
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529