Schneider Electric

XPSBAT12A1AP

safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw
XPSBAT12A1AP
XPSBAT12A1AP
XPSBAT12A1AP
XPSBAT12A1AP
XPSBAT12A1AP
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
1575,00 zł
1
Payment methods:
A total of 12 Parts In-Stock from 15 Distributors
Offer with manufacturer lead time
Ships in:On Request
Best price:
€104.01

Additional Information

Part Number
XPSBAT12A1AP
UNSPSC
32151802
Tariff Code
8536410050

Environment

Product Certifications
TÜV || cULus
Ambient Air Temperature For Operation
-25-55 °C
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Ambient Air Temperature For Storage
-25-85 °C
Relative Humidity
5-95 % non-condensing

Complementary

Number Of Outputs
3 on/off configurable pulsed output
Height
100 mm
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
24 V relay output
Minimum Output Current
20 mA relay output
[Ith] Conventional Free Air Thermal Current
12 A
Input/Output Type
semiconductor output 24 V DC, 20 mA Z1, not safety-related
Associated Fuse Rating
6 A gG NO relay output circuit IEC 60947-1
Local Signalling
LED green power power ON || LED red error error || LED yellow state 1 safety output instantaneous || LED yellow state 2 safety output delayed || LED yellow start 1 start || LED yellow start 2 start || LED yellow S12 safety input S12 || LED yellow S22 safety input S22
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.350 kg
Type Of Start
automatic/manual/monitored
Number Of Inputs
2 positive safety input 24 V DC 5
Time Delay Range
0...900 s off
Input Compatibility
normally closed circuit ISO 14119 || mechanical contact ISO 14119 || OSSD pair IEC 61496-1-2 || normally closed circuit ISO 13850 || 3-wire proximity sensors PNP
Power Consumption In Va
5 VA 24 V AC 50/60 Hz
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Auxiliary Contact Composition
2 NO immediate || 1 NO configurable
[Ui] Rated Insulation Voltage
250 V 2)IEC 60947-1
Power Consumption In W
2 W 24 V DC
Maximum Line Resistance
500 Ohm
Input Protection Type
internal, electronic
Width
22.5 mm
Depth
120 mm
Synchronisation Time Between Inputs
0.5 s || 2 s
Maximum Response Time On Input Open
20 ms

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Specifications

[Us] Rated Supply Voltage
24 V AC - 15...10 % || 24 V DC - 20...20 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSBAT
Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application
for emergency stop and protective guard applications || for OSSD monitoring
Safety Reliability Data
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.98E-09 for SS0 ISO 13849-1 || PFHd = 0.96E-09 for SS1 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.98E-09 for SS0 IEC 62061 || PFHd = 0.96E-09 for SS1 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.98E-09 for SS0 IEC 61508-1 || PFHd = 0.96E-09 for SS1 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit Type
NC pair || OSSD pair
Function Of Module
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE)
Safety Level
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508

Documents

Data Sheet

Download

CAD Models

Trace parts
Trace parts
Download

Related products