Inductive proximity sensors XS, inductive sensor XS7 15x32x8, PBT, Sn5mm, 12...24 VDC, cable 2 m
XS7F1A1NAL2
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
XS7F1A1NAL2
UNSPSC
39122230
Tariff Code
8536507000
Country of Origin
ID

Specifications

Electrical Connection
cable
[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection
Discrete Output Type
NPN
Discrete Output Function
1 NO
Type Of Output Signal
discrete
Range Of Product
Telemecanique Inductive proximity sensors XS
Cable Length
2 m
Sensor Name
XS7
Material
plastic
Size
8 mm
Wiring Technique
3-wire
Ip Degree Of Protection
IP68 conforming to IEC 60529
Series Name
general purpose
Body Type
fixed
Sensor Type
inductive proximity sensor
Detector Flush Mounting Acceptance
flush mountable
Switching Capacity In Ma
<= 100 mA DC overload and short-circuit protection
Sensor Design
flat form 15 x 32 x 8
Enclosure Material
PBT
Output Circuit Type
DC

Contractual warranty

Warranty
18 months

Complementary

Current Consumption
<= 10 mA no-load
Height
32 mm
Maximum Delay Response
0.1 ms
Status Led
output state 1 LED yellow)
Operating Zone
0-4 mm
Maximum Voltage Drop
<2 V closed)
Marking
CE
Net Weight
0.065 kg
Switching Frequency
<= 2000 Hz
Differential Travel
1...15% of Sr
Maximum Delay Recovery
0.1 ms
Maximum Delay First Up
5 ms
Supply Voltage Limits
10-36 V DC
Wire Insulation Material
PVC
Detection Face
frontal
Cable Composition
3 x 0.34 mm²
Width
15 mm
Front Material
PBT
Depth
8 mm

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP071001EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
C-tick || CSA || UL
Ambient Air Temperature For Operation
-25-70 °C
Vibration Resistance
25 gn +/- 2 mm 10-55 Hz)IEC 60068-2-6
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Storage
-40-85 °C

Documents

Data Sheet

Download

Related products