Schneider Electric

XU2S18PP340D

Safety thru beam pair photo electric sensors, Preventa Safety detection, security light curtain XU2 S, of body, Sn 8 m, 12...24 VDC, M12
XU2S18PP340D
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 3 Parts In-Stock from 10 Distributors

Additional Information

Part Number
XU2S18PP340D
UNSPSC
32151802
Tariff Code
8541498000
Country of Origin
FR

Specifications

Range Of Product
Telemecanique Safety light curtains XUSL
Product Or Component Type
safety thru-beam pair photo-electric sensors
Output Type
1 safety outputs OSSD PNP
[Sn] Nominal Sensing Distance
8-8 m
Device Short Name
XU2S

Contractual warranty

Warranty
18 months

Complementary

Electrical Connection
1 male connector M12 4 pins
Current Consumption
<= 35 mA no-load
Switching Frequency
500 Hz maximum
Maximum Delay Response
1 ms
Maximum Voltage Drop
<1.5 V closed)
Line Of Sight Type
along case axis
Marking
CE
Net Weight
0.155 kg
Tightening Torque
24 N.m fixing nut || 2 N.m connector
Function Available
built-in muting function || light or dark programmable switching
Maximum Delay Recovery
1 ms
Material
nickel plated brass case || PMMA (polymethyl methacrylate) lenses
Detection System
transmitter-receiver system
Switching Capacity In Ma
<= 100 mA overload and short-circuit protection)
[Us] Rated Supply Voltage
12...24 V DC 10...30 V reverse polarity protection

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111230EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI111208EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-25-55 °C
Standards
EN/IEC 61496-1 || EN/IEC 61496-2 || EN/IEC 60825-1
Shock Resistance
30 gn 3 axes : 3 times EN/IEC 60068-2-27
Vibration Resistance
7 gn 10-55 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Safety Reliability Data
PFH = 5.5E-7 1/h with muting function IEC 61508 || PFH = 4.6E-7 1/h IEC 61508
Safety Level
can reach PL = c associated with module XPSCM correctly wired EN/ISO 13849-1 || can reach category 2 associated with module XPSCM correctly wired EN/ISO 13849-1 || type 2 IEC 61496-1-2

Documents

Data Sheet

Download

Related products