Schneider Electric

XX318AU08EKAM12

Ultrasonic sensors XX, ultrasonic sensor cylindrical m18 12, 24 V
XX318AU08EKAM12
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
€111.84

Additional Information

Part Number
XX318AU08EKAM12
UNSPSC
41111960
Tariff Code
8543709650
Country of Origin
US

Specifications

[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection
Series Name
general purpose
Discrete Output Type
PNP/NPN
Beam Angle
10 °
Discrete Output Function
1 NO
Type Of Output Signal
discrete
Range Of Product
Telemecanique Ultrasonic sensors XX
Detection System
diffuse
Sensor Type
ultrasonic sensor
Electrical Connection
male connector M12 4 pins
Sensor Design
cylindrical M18
Sensor Name
XX3
[Sn] Nominal Sensing Distance
0.0381-0.0381 m fixed
[Sd] Sensing Range
0.038-0.0508 m
Material
plastic
Wiring Technique
4-wire
Ip Degree Of Protection
IP67 conforming to IEC 60529

Complementary

Thread Type
M18 x 1
Height
18 mm
Maximum Switching Current
100 mA overload and short-circuit protection
Minimum Size Of Detected Object
cylinder diameter 50.8 mm 4.732 m
Maximum Delay Response
1.5 ms
Maximum Delay Recovery
1.5 ms
Maximum Delay First Up
20 ms
Maximum Voltage Drop
1 V
Status Led
supply on 1 LED green) || output state 1 LED amber)
Supply Voltage Limits
10-28 V DC
[Sa] Assured Operating Distance
0.038-0.0508 m
Enclosure Material
PEI
Marking
CE
Width
18 mm
Front Material
silicone
Depth
95.5 mm
Blind Zone
0-31.8 mm
Current Consumption
100 mA
Maximum Differential Travel
12.7 mm

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL || cCSAus
Ambient Air Temperature For Operation
0-50 °C
Resistance To Electromagnetic Fields
10 V/m level 3 IEC 61000-4-3
Ambient Air Temperature For Storage
-40-80 °C
Standards
IEC 60947-5-2
Resistance To Electrostatic Discharge
8 kV level 4 IEC 61000-4-2
Vibration Resistance
+/-1 mm 10-55 Hz)IEC 60068-2-6
Shock Resistance
30 gn in all 3 axes 11 ms IEC 60068-2-27
Resistance To Fast Transients
1 kV level 3 IEC 61000-4-4

Documents

Data Sheet

Download

Related products