Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, right side, 2NC, ISO M20
XY2CJR17H29
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
XY2CJR17H29
UNSPSC
39122239
Tariff Code
8536509031
Country of Origin
ID

Specifications

Housing Colour
red RAL 3000
Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Overvoltage Category
class I EN/IEC 61140
Product Or Component Type
latching emergency stop rope pull switch
Device Short Name
XY2C

Complementary

Trigger Cable Maximum Length
30 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Reset
by pull button
Contacts Type And Composition
2 NC
Number Of Cables
1
Terminals Description Iso N°1
(11-22)NC || (21-22)NC
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
5-5 m
Mechanical Durability
100000 cycles
Positive Opening
with EN/IEC 60947-5-1
Cable Entry Number
1 tapped entry ISO M20 cable gland
Compatibility Code
XY2CJ
Body Material
zamak
[Ithe] Conventional Enclosed Thermal Current
10 A
Trigger Cable Anchor Point
RH side
Safety Reliability Data
B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking
CE
Cover Material
galvanised steel
Local Signalling
color indicator
Net Weight
0.669 kg
Tightening Torque
0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407002EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60204-1 || CSA C22.2 No 14 || EN/IEC 60947-5-5 || UL 508 || machinery directive 2006/42/EC || work equipment directive 2009/104/EC || EN/ISO 13850 || EN/IEC 60947-5-1
Product Certifications
UL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 IEC 60529 || IP67 IEC 60529

Documents

Data Sheet

Download

Related products