Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC+1 NO, Pg13.5
XY2CJS19
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
225,47 zł
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
Send request for price

Additional Information

Part Number
XY2CJS19
UNSPSC
39122239
Tariff Code
8536509065
Country of Origin
ID

Specifications

Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Product Or Component Type
latching emergency stop rope pull switch
Housing Colour
red RAL 3000
Overvoltage Category
class I EN/IEC 61140
Device Short Name
XY2C

Complementary

Reset
by pull button
Number Of Cables
1
Terminals Description Iso N°1
(31-32)NC || (21-22)NC || (13-14)NO
Short-Circuit Protection
6 A cartridge fuse gG EN/IEC 60269
Positive Opening
with EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current
6 A
Marking
CE
Head Material
PA (polyamide)
Local Signalling
color indicator
Net Weight
0.455 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1
Trigger Cable Maximum Length
20 m
Connections - Terminals
screw clamp terminal, 1 x 0.34...1 x 1 mm² || screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
Contacts Type And Composition
2 NC + 1 NO
[Ui] Rated Insulation Voltage
400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current
0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
5-5 m
Mechanical Durability
100000 cycles
Cable Entry Number
1 tapped entry Pg 13.5 cable gland
Compatibility Code
XY2CJ
Body Material
zamak
Trigger Cable Anchor Point
RH or LH side
Safety Reliability Data
B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Material
galvanised steel
Tightening Torque
0.8-1.2 N.m
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407003EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
machinery directive 2006/42/EC || UL 508 || EN/IEC 60947-5-1 || EN/ISO 13850 || EN/IEC 60204-1 || CSA C22.2 No 14 || work equipment directive 2009/104/EC || EN/IEC 60947-5-5
Product Certifications
UL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529 || IP67 IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC

Documents