Siemens 3VA2163-5KQ36-0AA0

BRKR 3VA21 3P 63A 55KA ETU8-LSIG BOX

(16 offers)
Image of the product 3VA2163-5KQ36-0AA0
A total of  1 Parts In-Stock from 1 Distributor
New: 1 pcs.
SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA21 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 63A 3-POLE Icu: (2.5KAIC AT 690V) (55KAIC AT 415V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES: CONNECTION WITH BOX TERMINAL / STEEL WRAP AROUND LUG. DIMENSIONS (W x H x D) IN: 4.1 x 7.1 x 4.2.

Suppliers

In-Stock Parts

These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
Register to See Company
Country: Germany
In Stock Updated 19/04/2024
  • Quantity: New: 1 pcs.

On Request Parts

These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country: Czech Republic
On Request Updated 19/04/2024
  • Quantity: New: 0 pcs.
On Request Updated 19/04/2024
  • Quantity: New Sealed: 0 pcs.
On Request Updated 19/04/2024
  • Quantity: New: 0 pcs.
On Request Updated 19/04/2024
  • Quantity: New Sealed: 0 pcs.
Register to See Company
Country: Germany
On Request Updated 19/04/2024
  • Quantity: New Sealed: 0 pcs.

Additional information

Part Number 3VA2163-5KQ36-0AA0
UPC 804766436307
Tariff Code 8536200020
RoHS Status Not RoHS compliance unknown
Country of origin CZ
Lifecycle status Active

Specifications

Country of Origin CZ
Number of poles 3
Rated voltage 690 V
Motor drive optional true
Motor drive integrated false
Degree of protection (IP) IP40
Rated permanent current Iu 63 A
With switched-off indicator false
Overload release current setting 25 A
Type of control element Rocker lever
Integrated earth fault protection true
Complete device with protection unit true
With integrated under voltage release false
DIN rail (top hat rail) mounting optional true
Suitable for DIN rail (top hat rail) mounting true
Adjustment range undelayed short-circuit release 95 A
Number of auxiliary contacts as change-over contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Type of electrical connection of main circuit Frame clamp
Position of connection for main current circuit Front side
Device construction Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release 38 A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 55 kA