Tripp Lite
PDU330AT6L2130
8.6kW 3-Phase Monitored Automatic Transfer Switch, 2 208V L21-30P Inputs, 1U (0U PDU Accessory Sold Separate)
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- PDU330AT6L2130
- UPC
- 037332191519
Overview
- UPC Code
- 037332191519
- PDU Type
- Monitored; Auto-Transfer Switch
Output
- Frequency Compatibility
- 50 / 60 Hz
- Output Receptacle Details
- 0U vertical output power distribution component is a required accessory; Order REQUIRED PDU accessory PDU3V20D354 (54 C13 outlets), PDU3V20D354A (42 C13 and 12 C19 outlets) or PDU3V20D354B (48 C13 and 6 C19 outlets)
- Output Capacity Details
- 8.6kW (208V) total capacity; 13.9A max per output phase (L1-L2, L2-L3, L3-L1), 12A max per C13 outlet
- Output Receptacles
- C13; C19
- Output Nominal Voltage
- 208
- Overload Protection
- 3 20A double-pole breakers (1 per breakered outlet bank)
Input
- PDU Input Voltage
- 208
- Maximum Input Amps
- 24
- PDU Plug Type
- (2) NEMA L21-30P
- Input Phase
- 3-Phase
- Input Cord Details
- Set of 2 inputs enable connection to separate PRIMARY and SECONDARY power sources
- Input Cord Length (ft.)
- 6
User Interface, Alerts & Controls
- Reported Load Segments
- Supports local display of A & B line INPUT CURRENT, INPUT VOLTAGE & FREQUENCY per phase, OUTPUT CURRENT, KW, VOLTAGE & POWER FACTOR per phase, TOTAL OUTPUT POWER (kW), PHASE IMBALANCE (%), TEMPERATURE (C/F), FAULT CODE and SCROLL IP
- Front Panel LCD Display
- Large 3-character display reports data for reported values; Additional 2 character identifies the measurement value or specific location the displayed measurement applies
- Front Panel LEDs
- Set of 6 LEDs indicate A/B input PREFERRED, AVAILABLE & IN USE status; Set of 5 LEDs label the measurement value displayed (AMPS, KW, VOLTS, HZ & POWER-FACTOR); One additional red LED reports BREAKER TRIP status
- Switches
- MODE and ENTER buttons enable navigation and viewing of all reported information
- Current Measurement Accuracy (Amps)
- +/-1%
- Voltage Measurement Accuracy (Volts)
- +/-1%
- Power Measurement Accuracy (Watts)
- +/-1%
Physical
- Form Factors Supported
- 1U rackmount ATS module; Separate purchase 0u vertical mount PDU outlet distribution bar sold separate (3 options available)
- Material of Construction
- Steel
- PDU Form Factor
- Horizontal (1U)
- Shipping Dimensions (hwd / in.)
- 5.00 x 27.95 x 41.54
- Shipping Weight (lbs.)
- 42.55
- Unit Dimensions (hwd / in.)
- 1.72 x 16.9 x 26
- Unit Weight (lbs.)
- 26.8
Environmental
- Storage Temperature Range
- -30°C to +50°C (-22°F to +122°F)
- Relative Humidity
- Up to 95% (non-condensing)
- Operating Elevation (ft.)
- 0-10,000
- Operating Elevation (m)
- 0-3000
Special Features
- Grounding Lug
- Included
Certifications
- Certifications
- Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), RoHS Complaint
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther