Tripp Lite
SM1000RM2UTAA
TAA SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, 6 Outlets
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332152718
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 1000
- Output kVA Capacity (kVA)
- 1
- Output Watt Capacity (Watts)
- 800
- Power Factor
- 0.8
- Nominal Voltage Details
- 120v nominal output in battery mode
- Frequency Compatibility
- 60 Hz
- Output Voltage Regulation (Line Mode)
- -21%, +8%
- Output Voltage Regulation (Battery Mode)
- +/- 5%
- Load Management Receptacles
- Two switchable two-outlet 5-15R load banks
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 110V; 115V; 120V
- Output Receptacles
- (6) 5-15R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 9.2A
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- 5-15P
- Input Circuit Breakers
- 10A
- UPS Input Cord Length (ft.)
- 10
- Recommended Electrical Service
- 15A 120V
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 5.3 min. (800w)
- Half Load Runtime (min.)
- 15 min. (400w)
- DC System Voltage (VDC)
- 24
- Battery Recharge Rate (Included Batteries)
- Less than 4 hours from 10% to 90%
- Internal UPS Replacement Battery Cartridge
- IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SM1000RM2UTAA UPS is equipped with a LCD front-panel screen, order Tripp Lite RBC24V-LCD (quantity 1) replacement battery; If your SM1000RM2UTAA UPS is equipped with LED front-panel indicators, order Tripp Lite RBC92-2U (quantity 1) replacement battery
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- No
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction
- Input voltages between 128 and 147 are reduced by 12%
- Undervoltage Correction
- Input voltages between 83 and 107 are boosted by 14%
User Interface, Alerts & Controls
- Front Panel LCD Display
- Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches
- 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
- Alarm Cancel Operation
- Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm
- Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 570
- UPS AC Suppression Response Time
- Instantaneous
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
- Minimum Required Rack Depth (inches)
- 15.5
- Optional Mounting Accessory Notes
- Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 318
- Primary UPS Height (mm)
- 88
- Primary UPS Width (mm)
- 441
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 8.80 x 18.50 x 23.00
- Shipping Weight (lbs.)
- 44.90
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 3.45 x 17.35 x 12.5
- UPS Power Module Weight (kg)
- 16.06
- UPS Power Module Weight (lbs.)
- 35.4
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 134
- Battery Mode BTU / Hr. (Full Load)
- 600
- AC Mode Efficiency Rating (100% Load)
- 95%
- Audible Noise
- 45 dBA maximum, front side 1m
Communications
- Network Management Cards
- SNMPWEBCARD ; TLNETCARD ; WEBCARDLX
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Network UPS Tools Compatibility
- NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
- Communications Interface
- USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 83
- High Voltage Transfer to Battery Power (Setpoint)
- 147
Special Features
- Grounding Lug
- Back panel grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances); TAA Compliant
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther