Tripp Lite
SMX1200XLHG
SmartPro 230V 1kVA 750W Medical-Grade Line-Interactive Tower UPS with 6 Outlets, Full Isolation, Expandable Runtime
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332140425
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 1000
- Output Watt Capacity (Watts)
- 750
- Nominal Voltage Details
- 230v nominal inverter output voltage
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Automatic frequency selection
- Output Voltage Regulation (Line Mode)
- -18%, +8%
- Output AC Waveform (Battery Mode)
- PWM sine wave
- Nominal Output Voltage(s) Supported
- 220V; 230V; 240V
- Output Receptacles
- (6) C13
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 5A
- Nominal Input Voltage(s) Supported
- 230V AC
- UPS Input Connection Type
- C14 inlet
- UPS Input Cord Length (ft.)
- 0.50
- Recommended Electrical Service
- 10A 230V
- Voltage Compatibility (VAC)
- 230
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 11 min. (750w)
- Half Load Runtime (min.)
- 27.5 min. (375w)
- Expandable Battery Runtime
- Supports extended runtime with optional BP36V15-2U (limit 1) and BP36V42-3U external battery pack (multi-pack compatible)
- External Battery Pack Compatibility
- BP36V15-2U (limit 1); BP36V42-3U (multi-pack compatible); BP36V27-2US (multi-pack compatible)
- DC System Voltage (VDC)
- 36
- Battery Recharge Rate (Included Batteries)
- Less than 4.5 hours from 10% to 90%
- Internal UPS Replacement Battery Cartridge
- RBC36SLT
- Battery Access
- Battery access door allows hot swap battery replacement without powering connected equipment off
- Typical Battery Lifespan
- 3-6 years, depending on usage
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC.
- Overvoltage Correction
- Input voltages between 245 and 274V AC are reduced by 9%
- Undervoltage Correction
- Input voltages between 183 and 199 are boosted by 10%
- Severe Undervoltage Correction
- Input voltages between 156 and 182 are boosted by 21%
User Interface, Alerts & Controls
- Switches
- Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
- Audible Alarm
- Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events using our Free Power Alert UPS management software.
- LED Indicators
- 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 340
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- UPS cooling via rear-exit fan
- Installation Form Factors Supported with Optional Accessories
- Wallmount (UPSWM - tower mounting kit)
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 231
- Primary UPS Height (mm)
- 323
- Primary UPS Width (mm)
- 191
- Shipping Dimensions (hwd / in.)
- 18.50 x 12.20 x 13.38
- Shipping Weight (lbs.)
- 48.80
- UPS Housing Material
- PVC
- UPS Power Module Dimensions (hwd, in.)
- 12.7 x 7.5 x 9.1
- UPS Power Module Weight (kg)
- 20.64
- UPS Power Module Weight (lbs.)
- 45.5
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 252.2
- Battery Mode BTU / Hr. (Full Load)
- 252.2
Communications
- Communications Interface
- USB; DB9 Serial
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 155
- High Voltage Transfer to Battery Power (Setpoint)
- 274
Special Features
- Grounding Lug
- Ground Potential Equalization Connector: POAG-S6/20
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
Certifications
- UPS Certifications
- CE; Tested to UL60601-1 (medical grade)
Warranty
- Product Warranty Period (International)
- 2-year limited warranty
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther