Tripp Lite
SU2200RTXLCDN
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332182982
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 2200
- Output kVA Capacity (kVA)
- 2.2
- Output Watt Capacity (Watts)
- 1800
- Output kW Capacity (kW)
- 1.8
- Power Factor
- 0.82
- Crest Factor
- 3:1
- Nominal Voltage Details
- 120V factory-default nominal voltage
- Frequency Compatibility
- 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
- Frequency Compatibility Details
- ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Output Voltage Regulation (Battery Mode)
- +/- 3%
- Load Management Receptacles
- Two switchable three-outlet 5-15/20R load banks
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- ON LINE MODE: Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts / 115V 1134 watts / 110V 1071 watts / 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
- Nominal Output Voltage(s) Supported
- 100V; 110V; 115V; 120V; 127V
- Output Receptacles
- (6) 5-15/20R; (1) L5-20R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 16A
- Nominal Input Voltage(s) Supported
- 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
- Nominal Input Voltage Description
- 120V factory default
- UPS Input Connection Type
- 5-20P
- Input Circuit Breakers
- 30A
- UPS Input Cord Length (ft.)
- 10
- Recommended Electrical Service
- 20A 120V
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 4 min. (1800w)
- Half Load Runtime (min.)
- 12 min. (900w)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility
- BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
- Expandable Runtime Description
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
- DC System Voltage (VDC)
- 48
- Battery Recharge Rate (Included Batteries)
- Less than 3 hours recharge to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- RBC94-2U
- Battery Access
- Front panel battery access
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
- Overvoltage Correction
- Corrects overvoltages to 150V (0-100% load)
- Undervoltage Correction
- Corrects undervoltages to 100V at full load (90V at 100V nominal)
- Severe Undervoltage Correction
- Corrects brownouts to 70V (70% load) & 55V (33% load)
User Interface, Alerts & Controls
- Front Panel LCD Display
- Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
- Switches
- 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
- Alarm Cancel Operation
- Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm
- Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators
- 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 570
- UPS AC Suppression Response Time
- Instantaneous
- UPS Dataline Suppression
- 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
- Minimum Required Rack Depth with External Battery Pack (cm)
- 66
- Minimum Required Rack Depth with External Battery Pack (in.)
- 26
- Minimum Required Rack Depth without External Battery Pack (cm)
- 61
- Minimum Required Rack Depth without External Battery Pack (in.)
- 24
- Optional Mounting Accessory Notes
- Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 483
- Primary UPS Height (mm)
- 89
- Primary UPS Width (mm)
- 445
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 8.90 x 19.90 x 23.50
- Shipping Weight (lbs.)
- 63.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 3.5 x 17.5 x 19
- UPS Power Module Weight (kg)
- 22.00
- UPS Power Module Weight (lbs.)
- 48.5
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 5 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 684
- AC Economy Mode BTU / Hr. (Full Load)
- 392
- Battery Mode BTU / Hr. (Full Load)
- 1085
- AC Economy Mode Efficiency Rating (100% Load)
- 94%
- Audible Noise
- 57 dBA at 1m front side
- Operating Elevation (m)
- Up to 3000m
Communications
- Network Monitoring Port Description
- Includes pre-installed WEBCARDLX Network Management Card interface; Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)
Line / Battery Transfer
- Transfer Time
- Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode
- Low Voltage Transfer to Battery Power (Setpoint)
- 100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load
- High Voltage Transfer to Battery Power (Setpoint)
- 150
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries
- Green Energy-Saving Features
- High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
Certifications
- UPS Certifications
- Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to UL1778 (USA)
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther