Tripp Lite
SU3000RTXL2U
SmartOnline 120V 3kVA 2.7kW On-Line Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332197023
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 3000
- Output kVA Capacity (kVA)
- 3.00
- Output Watt Capacity (Watts)
- 2700
- Output kW Capacity (kW)
- 2.70
- Power Factor
- 0.9
- Crest Factor
- 3:1
- Nominal Voltage Details
- 120V default
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Accepts 40 to 70Hz input frequency. Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates to 70% of normal levels during frequency conversion operation.
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Load Management Receptacles
- Two switchable three-outlet load banks
- Output Circuit Breakers
- 20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- INVERTER SHORT-CIRCUIT PROTECTION: Inverter short-circuit protection is electrically protected; OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 30 seconds, 150% for 10 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of 120V ±10%) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits of 120V ±10%).
- Nominal Output Voltage(s) Supported
- 100V; 110V; 115V; 120V; 127V
- Output Receptacles
- (6) 5-15/20R; (1) L5-30R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 24A maximum
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- L5-30P
- Recommended Electrical Service
- 30A 120V
- Input Phase
- Single-Phase
- Input Cord Length (ft.)
- 10
Battery
- Full Load Runtime (min.)
- 4.8 min. (2700w)
- Half Load Runtime (min.)
- 13.8 min. (1350w)
- Expandable Battery Runtime
- Supports extended runtime with optional external battery packs
- External Battery Pack Compatibility
- BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible)
- DC System Voltage (VDC)
- 72
- Battery Recharge Rate (Included Batteries)
- Less than 8.1 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- See RBC selector guide (replacement battery part number is also labeled on the internal battery door)
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Overvoltage Correction
- ONLINE MODE: 2% output voltage regulation during overvoltages to 150
- Undervoltage Correction
- 2% output voltage regulation during undervoltages to 80V (66-100% load)
- Severe Undervoltage Correction
- 2% output voltage regulation during undervoltages to 70V (33-66% load) or 60V (under 33% load)
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch
- Audible Alarm
- Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
- LED Indicators
- 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 504
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Includes 4 post rackmount installation accessories
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )
- Minimum Required Rack Depth with External Battery Pack (cm)
- 77
- Minimum Required Rack Depth with External Battery Pack (in.)
- 30.25
- Minimum Required Rack Depth without External Battery Pack (cm)
- 74
- Minimum Required Rack Depth without External Battery Pack (in.)
- 29.25
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 616
- Primary UPS Height (mm)
- 88
- Primary UPS Width (mm)
- 438
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 9.45 x 23.62 x 29.92
- Shipping Weight (lbs.)
- 87.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 3.46 x 17.24 x 24.25
- UPS Power Module Weight (kg)
- 31.17
- UPS Power Module Weight (lbs.)
- 68.72
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
- Relative Humidity
- 5 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 531
- AC Economy Mode BTU / Hr. (Full Load)
- 484.5
- Battery Mode BTU / Hr. (Full Load)
- 1037
- AC Economy Mode Efficiency Rating (100% Load)
- 95%
- Audible Noise
- 50 dBA max, front-side @ 1m
Communications
- Network Management Cards
- WEBCARDLX
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports and modify the UPS Power Strategy settings download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
- Low Voltage Transfer to Battery Power (Setpoint)
- 80V (100% load), 70V (66% load), 60V (33% load)
- High Voltage Transfer to Battery Power (Setpoint)
- 150
Special Features
- Grounding Lug
- Includes back-panel grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Hot swappable batteries
- Green Energy-Saving Features
- High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
Certifications
- UPS Certifications
- ENERGY STAR Qualified; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
- UPS Certification Details
- UL1778 5TH; CSA 22.2-107.3-14; FCC CLASS A; ENERGY STAR Version 2.0 Qualified
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther