Tripp Lite
SU6000RT4UHVG
SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, C19
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332157232
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 6000
- Output kVA Capacity (kVA)
- 6
- Output Watt Capacity (Watts)
- 5400
- Output kW Capacity (kW)
- 5.4
- Power Factor
- 0,9
- Crest Factor
- 3:1
- Nominal Voltage Details
- Voltage selection via front panel LCD interface
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Output frequency matches input nominal on startup; Frequency conversion mode enable conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Output Receptacle Details
- Output receptacle and input connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
- Output Circuit Breakers
- Two 20A breakers protect 2 C19 outlets each
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- Output capacity de-rates to 4992 watts when used at 208V with optional L6-30P line cord; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
- Nominal Output Voltage(s) Supported
- 200V; 208V; 220V; 230V; 240V
- Output Receptacles
- (4) C19
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
- Nominal Input Voltage(s) Supported
- 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
- Nominal Input Voltage Description
- Factory configured to 208V
- UPS Input Connection Type
- Hardwire
- UPS Input Connection Description
- Supports North American 208/240V input (L1,L2,G) or International 230/220/240V (L,N,PE) input wiring; Optional SU30ACORD offers NEMA L6-30P input
- Recommended Electrical Service
- 40A (200/208v); 30-32A (220/230/240v)
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 2 minutes (5400 watts)
- Half Load Runtime (min.)
- 8.5 minutes (2700 watts)
- Expandable Battery Runtime
- Runtime is expandable with external battery packs
- External Battery Pack Compatibility
- BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH
- DC System Voltage (VDC)
- 192
- Battery Recharge Rate (Included Batteries)
- 6 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- RBC5-192
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable internal batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Overvoltage Correction
- Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
- Undervoltage Correction
- Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
User Interface, Alerts & Controls
- Front Panel LCD Display
- Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats
- Switches
- Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.
- Alarm Cancel Operation
- Alarm cancel switch
- Audible Alarm
- Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- LED Indicators
- 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 2595
- UPS AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- Fans
- Included Mounting Accessory Description
- Includes 4 post rackmount installation accessories
- Maximum Device Depth (in.)
- 20.7
- Minimum Required Rack Depth with External Battery Pack (cm)
- 73
- Minimum Required Rack Depth with External Battery Pack (in.)
- 28.67
- Minimum Required Rack Depth without External Battery Pack (cm)
- 61
- Minimum Required Rack Depth without External Battery Pack (in.)
- 24.17
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 525
- Primary UPS Height (mm)
- 174
- Primary UPS Width (mm)
- 445
- Rack Height
- 4U
- Shipping Dimensions (hwd / in.)
- 34.00 x 24.00 x 26.00
- Shipping Weight (lbs.)
- 190.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 6.85 x 17.5 x 20.67
- UPS Power Module Weight (kg)
- 48.99
- UPS Power Module Weight (lbs.)
- 108
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 1767
- AC Economy Mode BTU / Hr. (Full Load)
- 768
- Battery Mode BTU / Hr. (Full Load)
- 2279
- AC Mode Efficiency Rating (100% Load)
- 90%
- AC Economy Mode Efficiency Rating (100% Load)
- 96%
- Operating Elevation (ft.)
- 0-3000m (0 to 10,000 ft.)
- Audible Noise
- 60 dBA at front side 1 meter
- Operating Elevation (m)
- 0-3000 m
Communications
- Network Management Cards
- SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
- Network Monitoring Port Description
- Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB, DB9 serial and EPO cables included
- WatchDog Compatibility
- Yes
- Communications Interface
- USB
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
- Transfer Time (Economy Mode)
- 8 ms. typical power failure response in optional economy mode
- Low Voltage Transfer to Battery Power (Setpoint)
- 156V (full load) / 100V (50% load or less, derates linearly)
- High Voltage Transfer to Battery Power (Setpoint)
- 280V (full load) / 300V (90% load or less)
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch
Certifications
- UPS Certifications
- CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to UL1778 (USA)
- UPS Certification Details
- IEC 61000-4-5 1995 B Surge Immunity
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther