SmartOnline 120/208V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
SU80K
SU80K
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Overview

UPC Code
037332141330
UPS Type
On-Line

Output

Output Volt Amp Capacity (VA)
80000
Output kVA Capacity (kVA)
80
Output Watt Capacity (Watts)
64000
Output kW Capacity (kW)
64
Power Factor
0.8
Crest Factor
3:1
Frequency Compatibility
50 / 60 Hz
Output Voltage Regulation (Line Mode)
+/-1%
Output Voltage Regulation (Battery Mode)
+/-1%
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery Mode)
Pure Sine wave
Nominal Output Voltage(s) Supported
120/208V 3-PH Wye
Output Receptacles
Hardwire
Individually Controllable Load Banks
No

Input

Nominal Input Voltage(s) Supported
120/208V 3-PH Wye
Nominal Input Voltage Description
3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection Type
Hardwire
Input Phase
3-Phase

Battery

Expandable Battery Runtime
Battery set sold separate
External Battery Pack Compatibility
BP480V200; BP480V300; BP480V400; BP480V40C; BP480V500
Expandable Runtime Description
External battery pack wiring is contractor supplied
DC System Voltage (VDC)
+/- 240VDC
Battery Recharge Rate (Included Batteries)
2 - 4 hours from 10% to 90%
Battery Replacement Description
Hot-swappable, replaceable batteries
Expandable Runtime
Yes

Voltage Regulation

Voltage Regulation Description
Online, double-conversion power conditioning
Overvoltage Correction
Maintains continuous operation without using battery power during overvoltages to 150 / 260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal
Undervoltage Correction
Maintains continuous operation without using battery power during brownout / undervoltage conditions to 94 / 163 (3-Phase, 4-Wire, wye)

User Interface, Alerts & Controls

Switches
ON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. LCD Display Control Buttons browses through and selects items displayed on LCD screen. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass breaker bypasses the UPS's inverter during maintenance.
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm
Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
LED Indicators
4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions

Surge / Noise Suppression

EMI / RFI AC Noise Suppression
Yes
AC Suppression Joule Rating
4675
AC Suppression Response Time
Instantaneous

Physical

Cooling Method
Fans
Installation Form Factors Supported with Included Accessories
Tower
Primary Form Factor
Tower
Primary UPS Depth (mm)
986
Primary UPS Height (mm)
1,697
Primary UPS Width (mm)
521
Shipping Dimensions (hwd / in.)
75.00 x 28.50 x 48.00
Shipping Weight (lbs.)
1642.50
UPS Housing Material
Steel
UPS Power Module Dimensions (hwd, in.)
66.8 x 20.5 x 38.8
UPS Power Module Weight (kg)
654.99
UPS Power Module Weight (lbs.)
1444

Environmental

Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
18665
Battery Mode BTU / Hr. (Full Load)
19005

Communications

Network Management Cards
SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable
DB9 cabling included
Communications Interface
DB9 Serial; Slot for SNMP/Web interface

Line / Battery Transfer

Transfer Time
No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint)
Maintains continuous operation during undervoltages as low as 94 / 163V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
High Voltage Transfer to Battery Power (Setpoint)
Maintains continuous operation during overvoltages as high as 150 / 260V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.

Special Features

Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features
High efficiency economy mode operation; Schedulable daily hours of economy mode operation

Certifications

UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)

Warranty

Product Warranty Period (U.S. & Canada)
1-year limited warranty