Tripp Lite
SUINT1000LCD2UN
208/230V 1000VA 900W Double-Conversion UPS - 6 Outlets, Extended Run, WEBCARDLX, LCD, USB, DB9, 2U
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332253569
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 1000
- Output kVA Capacity (kVA)
- 1
- Output Watt Capacity (Watts)
- 900
- Output kW Capacity (kW)
- 0.9
- Power Factor
- 0,9
- Crest Factor
- 3:1
- Nominal Voltage Details
- Nominal output voltage is user configured on first power-on
- Frequency Compatibility
- 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
- Frequency Compatibility Details
- Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Included Output Power Cables
- Includes 2 C13 to C14 power cables
- Load Management Receptacles
- Two switchable 2-outlet load banks
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 630 watts for 208/220/230/240V output voltages; Max output is 720W (504W in Frequency Conversion mode) at 200V output voltage OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
- Nominal Output Voltage(s) Supported
- 200V; 208V; 220V; 230V; 240V
- Output Receptacles
- (6) C13
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 4.99A
- Nominal Input Voltage(s) Supported
- 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
- UPS Input Connection Type
- C14 inlet
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 4.7 min. (900w)
- Half Load Runtime (min.)
- 12.3 min. (450w)
- Expandable Battery Runtime
- Supports extended runtime with optional external battery packs
- External Battery Pack Compatibility
- BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V36-2US (multi-pack compatible); BP24V70-3U (multi-pack compatible)
- DC System Voltage (VDC)
- 24
- Battery Recharge Rate (Included Batteries)
- Less than 4.1 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- RBC24S
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, replaceable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Overvoltage Correction
- 2% output voltage regulation during overvoltages to 288V
- Undervoltage Correction
- 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
User Interface, Alerts & Controls
- Front Panel LCD Display
- Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
- Switches
- 5 front panel switches: On/Off, Up, Down and Escape
- Alarm Cancel Operation
- Power-fail alarm can be silenced by following on-screen prompts
- Audible Alarm
- Audible alarm indicates power failure, low battery, overload and fault
- LED Indicators
- 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
Surge / Noise Suppression
- UPS Dataline Suppression Details
- Single line dialup / network dataline protection included
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Joule Rating
- 627
- AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
- Minimum Required Rack Depth with External Battery Pack (cm)
- 47
- Minimum Required Rack Depth with External Battery Pack (in.)
- 18.63
- Minimum Required Rack Depth without External Battery Pack (cm)
- 45
- Minimum Required Rack Depth without External Battery Pack (in.)
- 17.88
- Optional Mounting Accessory Notes
- Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 397
- Primary UPS Height (mm)
- 88
- Primary UPS Width (mm)
- 438
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 9.60 x 19.80 x 23.50
- UPS Housing Material
- Metal
- UPS Power Module Dimensions (hwd, in.)
- 3.46 x 17.24 x 15.63
- UPS Power Module Weight (kg)
- 12.70
- UPS Power Module Weight (lbs.)
- 28
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
- Relative Humidity
- 5 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 245
- AC Economy Mode BTU / Hr. (Full Load)
- 128
- Battery Mode BTU / Hr. (Full Load)
- 500
- AC Mode Efficiency Rating (100% Load)
- >93%
- AC Economy Mode Efficiency Rating (100% Load)
- >96%
- Audible Noise
- <45dB at front side 1M
Communications
- PowerAlert Software
- Available for download at www.tripplite.com
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- Contact closure; DB9 Serial; EPO (emergency power off); Included network card; Slot for SNMP/Web interface; USB (HID enabled)
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode; 3-9 ms. transfer time during economy mode operation
- Low Voltage Transfer to Battery Power (Setpoint)
- 160V (100% load), 140V (66% load), 120V (33% load)
- High Voltage Transfer to Battery Power (Setpoint)
- 288V
Special Features
- Grounding Lug
- Back panel grounding lug included
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries
- Green Energy-Saving Features
- High efficiency economy mode operation; Individually controllable load banks
Certifications
- UPS Certifications
- CE; ENERGY STAR Qualified; Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to SASO (Saudi Arabia); Tested to UL1778 (USA)
- UPS Certification Details
- IEC62040-1:2008+A1; UL1778 5th; Meets EMI approvals EN62040-2 (Cat C2), FCC Class A
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther