Wago

2205-7541

Multilevel installation terminal block; with operating slots and push-button; 4 mm²; with N-disconnect slide link; NT/L/PE; Push-in CAGE CLAMP®; 4,00 mm²; gray
2205-7541
2205-7541
2205-7541
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Ratings Per Iec/En

Ratings per
IEC/EN 60947-7-1
Ratings (note)
Potential – ground
Nominal voltage (III/3)
250 V
Rated impulse voltage (III/3)
4 kV
Rated current
31 A
Current at conductor cross-section (max.) mm²
35 A
Legend (ratings)
(III / 3) ≙ Overvoltage category III / Pollution degree 3

Ratings Per Iec/En 2

Ratings per 2
IEC/EN 60947-7-1
Ratings (note) 2
Potential – potential
Rated voltage (III/3) 2
400 V
Rated surge voltage (III/3) 2
6 kV
Rated current 2
31 A
Current at conductor cross-section (max.) 2
35 A

Environmental Requirements

Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C

Physical Data

Width
6.2 mm / 0.244 inches
Height
123.5 mm / 4.862 inches
Depth from upper-edge of DIN-rail
45.6 mm / 1.8 inches

Material Data

Note (material data)
<a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
Color
Gray
Material group
I
Insulation material
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.373 MJ
Weight
31.418 g

Mechanical Data

Potential marking
NT/L/PE
Mounting type
DIN-35 rail
Marking level
Center/side marking

Connection 2

Actuation type 2
Push-button

Specifications

Product Group Code
0036

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4066966165258
Customs tariff number
85369010000

Power Loss

Power loss, per pole (potential)
1.922 W
Rated current IN for specified power loss
31 A
Resistance value for specified, current-dependent power loss
0.001 Ω

Connection 1

Connection technology
Push-in CAGE CLAMP®
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
4 mm²
Solid conductor
0.5 … 6 mm² / 20 … 10 AWG
Solid conductor; push-in termination
1.5 … 6 mm² / 14 … 10 AWG
Fine-stranded conductor
0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with insulated ferrule
0.5 … 4 mm² / 20 … 12 AWG
Fine-stranded conductor; with ferrule; push-in termination
1.5 … 4 mm² / 18 … 12 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
11 … 13 mm / 0.43 … 0.51 inches
Wiring direction
Front-entry wiring