Wago

788-546

Relay module; Nominal input voltage: 24 VAC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm
788-546
788-546
788-546
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 1 Part In-Stock from 8 Distributors

Additional Information

Part Number
788-546
UPC
4050821226826
Tariff Code
85364900990
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Switching relay
Class Code : EC001437
Version : 7

Basic Relay

WAGO Basic Relay
788-946

Safety And Protection

Rated voltage
250 V
Rated surge voltage
4 kV
Pollution degree
3
Dielectric strength (control/load circuit) (AC, 1 min)
5 kVrms
Dielectric strength (open contact) (AC, 1 min)
1 kVrms
Dielectric strength (load/load circuit) (AC, 1 min)
2.5 kVrms
Safety information
A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.
Protection type
IP20

Load Circuit

Number of changeover/switchover contacts
2
Contact material (relay)
AgNi
Limiting continuous current
8 A
Inrush current (resistive) max.
(AC) 16 A / 0.02 s; (AC) 12 A / 4 s
Switching voltage (max.)
AC 250 V
Switching power (resistive) max.
AC 2000 VA; DC (see load limit curve)
Switching capacity
AC-15: 1.5 A / AC 240 V; DC-13: 1 A / DC 24 V
Recommended minimum load
12 V / 10 mA
Pull-in time (typ.)
15 ms
Drop-out time (typ.)
8 ms
Bounce time (typ.)
7 ms
Electrical life (NO; resistive load; 23 °C)
10 x 10³ switching operations
Mechanical life
5 x 10⁶ switching operations
Switching frequency with/without load (max.)
6 min-1 / 300 min-1

Environmental Requirements

Ambient temperature (operation at UN)
-40 … +70 °C
Ambient temperature UL (operation at UN)
-40 … +50 °C
Ambient temperature (storage)
-40 … +70 °C
Processing temperature
-25 … +50 °C
Temperature range of connection cable
≥ (Tambient + 20 K)

Connection Data

Connection technology
Push-in CAGE CLAMP®
Solid conductor
0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor
0.34 … 2.5 mm² / 22 … 14 AWG
Strip length
9 … 10 mm / 0.35 … 0.39 inches

Control Circuit

Nominal input voltage UN
AC 24 V
Input voltage range
±10 %
Nominal input current at UN
32 mA

Physical Data

Width
15 mm / 0.591 inches
Height
86 mm / 3.386 inches
Depth from upper-edge of DIN-rail
73 mm / 2.874 inches

Material Data

Fire load
0.669 MJ
Weight
46.407 g

Standards And Specifications

Standards/specifications
EN 61010-2-201 || EN 61810-1 || EN 61373 || UL 508

Mechanical Data

Mounting type
DIN-35 rail

Specifications

Product Group Code
0006

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4050821226826
Customs tariff number
85364900990

Notes

Safety information
A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.
Note
Reinforced insulation between coil and contactsTo protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Signaling

Status indicator
Red LED || Mechanical