Weidmuller
1064330000
VSSC6TRCLFG60VAC/DC0.5A
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Additional Information
- Part Number
- 1064330000
Further Details Of Approvals
- GOST certificate
- GOST-Zertifikat
General Data
- Colour
- black
- Design
- Terminal
- Isolating function
- Yes
- Optical function display
- No
- Protection degree
- IP20
- Rail
- TS 35
- Segment
- Measurement - Monitoring - Setting
- Testing option
- Functional screw with test plug receptacle, connections 1, 2, 4, 5
- UL 94 flammability rating
- V-0
- Version
- Surge protection for measurement and control
Probability Of Failure
- Λges
- 29
- MTTF
- 3,936 Years
- PFH in 1*10
- 1.95
- SFF
- 93.28 %
- SIL PAPER
- SIL Paper
- SIL in compliance with IEC 61508
- 3
Approvals
- Approvals
- CE, CSAEX, EAC, FUSAFETY, OEVE, UL
- ROHS
- Conform
- UL File Number Search
- E311081
Insulation Coordination Acc. To En 50178
- Pollution severity
- 2
- Surge voltage category
- III
Rated Data Iec / En
- Dielectric strength at FG against PE
- ≥ 500 V
- Discharge current I
- 2.5 kA
- Discharge current, max. (8/20 µs)
- 10 kA
- Fuse
- 0.5 A
- Insertion loss
- 250 MHz
- Lightning test current I
- 0.5 kA
- Lightning test current, I
- 0.5 kA
- Max. continuous voltage, Uc (AC)
- 75 V
- Max. continuous voltage, Uc (DC)
- 106 V
- Number of poles
- 1
- Overload - failure mode
- Modus 2
- Protection level U
- ≤ 1550 V
- Protection level on output side Wire-wire 1 kV/µs, typically
- 200 V
- Protection level, U
- 260 V
- Pulse-reset capacity
- ≤ 20 ms
- Rated current I
- 500 mA
- Rated voltage (AC)
- 60 V
- Rated voltage (DC)
- 85 V
- Requirements category acc. to IEC 61643-21
- C2, C3, D1
- Signal transmission properties (-3 dB)
- 270 Mhz
- Standards
- IEC 61643-21, HART-compatible
- Surge current-carrying capacity C2
- 2.5 kA 8/20 µs 5 kV 1.2/50 µs
- Surge current-carrying capacity C3
- 50 A 10/1000 μs
- Surge current-carrying capacity D1
- 0.5 kA 10/350 μs
- Voltage type
- AC/DC
- Volume resistance
- 1.8 Ω 10 %
Dimensions And Weights
- Width
- 6.2 mm
- Width (inches)
- 0.244 inch
- Height
- 88.5 mm
- Height (inches)
- 3.484 inch
- Depth
- 81 mm
- Depth (inches)
- 3.189 inch
- Net weight
- 44 g
Csa Protection Data
- Gas group C
- IIB
- Gas group D
- IIA
- Gas groups A, B
- IIC
- Input current, max. I
- 500 mA
- Input voltage, max. U
- 106 V
- Internal capacity, max. C
- 1 nF
- Internal inductance, max. L
- 0 µH
Connection Data
- Type of connection
- Screw connection
- Tightening torque, min.
- 0.5 Nm
- Tightening torque, max.
- 0.8 Nm
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 4 mm²
- Wire cross-section, solid, min.
- 0.5 mm²
- Wire cross-section, solid, max.
- 6 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), min.
- 0.5 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), max.
- 4 mm²
- Connection cross-section, stranded, min.
- 0.5 mm²
- Connection cross-section, stranded, max.
- 4 mm²
Rated Data Ul
- Certificate No. (UL)
- E311081
- UL certificate
- UL Zertifikat
Tender Specification Sheets
- Long specification
- Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground driven signal circuit with 60 V UC, 2-wire technology. Each signal path can be opened using an isolator. A current loop with max. 0.5 A can be protected here. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
- Short specification
- Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground driven signal circuit with 2-wire technology and a potential-free earth cable.Each signal path can be opened using an isolator. Version: 60V UC
Classifications
- ETIM 6.0
- EC000943
- ETIM 7.0
- EC000943
- EClass 9.0
- 27-13-08-07
- EClass 9.1
- 27-13-08-07
- EClass 10.0
- 27-13-08-07
- UNSPSC
- 30-21-19-21
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Temperatures
- Humidity
- 5...96 %
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature, max.
- 80 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -40 °C...70 °C
- Storage temperature
- -40 °C...80 °C
Ratings Iecex/Atex/Cul
- CUL certificate
- cUL Certificate
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther