Weidmuller

1176080000

ACT20M-2CI-2CO-ILP-S...
1176080000
1176080000
1176080000
Part Number
1176080000
Free Shipping!
1
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
0 pcs.
On Request
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original packaging, factory sealed.
Delivery time:
from2business days
Delivery from:
CZ
CZ
IT
IT
RO
RO
PL
PL
PT
PT
LV
LV
GB
GB
FR
FR
DE
DE
NL
NL
ES
ES

Available Offers (15)

1176080000 product image
Weidmuller

1176080000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
CZTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
1176080000 product image
Weidmuller

1176080000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
1176080000 product image
Weidmuller

1176080000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ROTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Free Shipping!
1176080000 product image
Weidmuller

1176080000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
CZTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Free Shipping!
1176080000 product image
Weidmuller

1176080000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
Offer with manufacturer lead time
Ships in:On Request
Best price:
€177.66

Additional Information

Part Number
1176080000

General Data

Accuracy
< 0.1 % of measuring range
Configuration
none
Galvanic isolation
2-way isolator
Power consumption
30 mW per channel
Rail
TS 35
Step response time
≤ 5 ms
Temperature coefficient
≤ 0.01 % / °C
Voltage supply
Loop powered, via 4…20 mA input

Probability Of Failure

MTBF
699 Years

Approvals

Approvals
CULUS, DETNORVER, DNV GL, EAC, FMEX, IECEXKEM, KEMAATEX
ROHS
Conform
UL File Number Search
E337701

Dimensions And Weights

Width
6.1 mm
Width (inches)
0.24 inch
Height
112.5 mm
Height (inches)
4.429 inch
Depth
114.3 mm
Depth (inches)
4.5 inch
Net weight
97 g

Connection Data

Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14

Tender Specification Sheets

Long specification
Standard signal passive isolator2-channel passive isolator in 6.1 mm width input-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error               < 0,1 % v. E. Limit frequency 100 Hz Auxiliary power                                     0/4...20 mA input current loop Power loss approx. 1.3 W Ambient temperature range -25 °C...+70 °CIsolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-2CI-2CO-ILP-S
Short specification
Standard signal passive isolator2-channel signal passive isolator in 6.1 mm width with input current loop feed,for transmitting and isolating analogue DC current signals from 0/4 to 20 mA

Input

Number of inputs
2
Sensor
Current source
Input current
0...20 mA, 4…20mA
Voltage drop, current input
1.25 V + 0.015 Vout @25°C
Input frequency
100 Hz

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20

Output

Number of outputs
2
Output current
0...20 mA, 4...20 mA
Cut-off frequency (-3 dB)
100 Hz
Load impedance current
≤600 Ω (channel 1 + 2)

Product Information

Product information
The ACT20M-CI-CO-ILP-S passive isolator isolates standard analogue current signals. An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. Power is supplied through the input measuring circuit (input loop-powered). The passive isolator ACT20M-2CI-2CO-ILP-S offers the same functionality, but has two galvanically isolated channels.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Data For Ex Applications (Atex)

Marking
II 3 G Ex nA IIC T4 Gc

Insulation Coordination

EMC standards
IEC 61326-1, NE 21
Galvanic isolation
2-way isolator
Insulation voltage
2.5 kVeff
Pollution severity
2
Rated voltage
300 Veff
Surge voltage category
II

Temperatures

Humidity
40 °C / 93 % rel. humidity, no condensation
Operating temperature, max.
70 °C
Operating temperature, min.
-25 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-40 °C
Operating temperature
-25 °C...70 °C
Ambient temperature
-25 °C...+70 °C
Storage temperature
-40 °C...85 °C

Ratings Iecex/Atex/Cul

Certificate No. (ATEX)
KEMA10ATEX0183X
Certificate No. (IECEX)
IECEXKEM10.0090X
Certificate no. (cULus)
E337701