Weidmuller

1235840000

BCF 3.81/10/180ZE SN OR BX
1235840000
1235840000
1235840000
1235840000
1235840000
1235840000
1235840000
1235840000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Rated Data Acc. To Ul 1059

Institute (cURus)
cURus
Certificate No. (cURus)
E60693
Rated voltage (Use group B / UL 1059)
300 V
Rated voltage (Use group D / UL 1059)
300 V
Rated current (Use group B / UL 1059)
10 A
Rated current (Use group D / UL 1059)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 16
Reference to approval values
Specifications are maximum values, details - see approval certificate.

Approvals

Approvals
cURus, EAC
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Width
38.19 mm
Width (inches)
1.504 inch
Height
9.3 mm
Height (inches)
0.366 inch
Depth
34.6 mm
Depth (inches)
1.362 inch
Net weight
8.5 g

Rated Data Acc. To Iec

Tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. number of poles (Tu=20°C)
17.5 A
Rated current, max. number of poles (Tu=20°C)
17.5 A
Rated current, min. number of poles (Tu=40°C)
17.5 A
Rated current, max. number of poles (Tu=40°C)
16.3 A
Rated voltage for surge voltage class / pollution degree II/2
320 V
Rated voltage for surge voltage class / pollution degree III/2
160 V
Rated voltage for surge voltage class / pollution degree III/3
160 V
Rated impulse voltage for surge voltage class/ pollution degree II/2
2.5 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2
2.5 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3
2.5 kV
Short-time withstand current resistance
3 x 1s with 76 A

Material Data

Insulating material
PA 66 GF 30
Colour
orange
Colour of operational elements
black
Material of operational elements
PPA GF
Colour chart (similar)
RAL 2000
Insulating material group
II
Comparative Tracking Index (CTI)
≥ 550
Insulation strength
≥ 108 Ω
UL 94 flammability rating
V-0
GWFI
960 °C
Contact material
Copper alloy
Contact surface
tinned
Layer structure of plug contact
4-8 µm Sn
Storage temperature, min.
-25 °C
Storage temperature, max.
55 °C
Max. relative humidity during storage
80 %
Operating temperature, min.
-50 °C
Operating temperature, max.
120 °C
Temperature range, installation, min.
-25 °C
Temperature range, installation, max.
120 °C

Classifications

ETIM 6.0
EC002638
ETIM 7.0
EC002638
EClass 9.0
27-44-03-09
EClass 9.1
27-44-03-09
EClass 10.0
27-44-03-09

System Parameters

Product family
OMNIMATE Signal - series BC/SC 3.81
Type of connection
Field connection
Wire connection method
PUSH IN, Tension-clamp connection
Pitch in mm (P)
3.81 mm
Pitch in inches (P)
0.15 inch
Conductor outlet direction
180°
Number of poles
10
L1 in mm
34.29 mm
L1 in inches
1.35 inch
Number of rows
1
Pin series quantity
1
Rated cross-section
1 mm²
Touch-safe protection acc. to DIN VDE 57 106
Safe from finger touch
Touch-safe protection acc. to DIN VDE 0470
IP 20
Volume resistance
6.00 mΩ
Can be coded
Yes
Stripping length
9 mm
Actuating force actuating element, max.
40 N
Screwdriver blade
0.4 x 2.5
Screwdriver blade standard
DIN 5264
Plugging cycles
25
Plugging force/pole, max.
8 N
Pulling force/pole, max.
7 N

Packing

Packaging
Box
VPE length
45 mm
VPE width
130 mm
VPE height
230 mm

Notes

Notes
Additional colours on request Crimp shape A for wire-end ferrules with crimping tools PZ 1,5 (order no. 9005990000) or PZ 6/5 (order no. 9011460000) for larger wire cross-sections recommended. Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Conductors suitable for connection: 1.5 mm² with wire-end ferrule with plastic collar, DIN 46 228/1, with a rated voltage of 125V/2.5 kV with III/3 or 250 V/2.5 kV with II/2
IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.

Conductors Suitable For Connection

Clamping range, min.
0.14 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Solid, min. H05(07) V-U
0.14 mm²
Solid, max. H05(07) V-U
1.5 mm²
Flexible, min. H05(07) V-K
0.14 mm²
Flexible, max. H05(07) V-K
1.5 mm²
W. plastic collar ferrule, DIN 46228 pt 4, min.
0.25 mm²
W. plastic collar ferrule, DIN 46228 pt 4, max.
1 mm²
W. wire end ferrule, DIN 46228 pt 1, min.
0.25 mm²
W. wire end ferrule, DIN 46228 pt 1, max.
1.5 mm²
Plug gauge in accordance with EN 60999 a x b; ø
2.4 mm x 1.5 mm; 1.9mm
Reference text
The outside diameter of the plastic collar should not be larger than the pitch (P).
Max. clamping range
1.5 mm²

Rated Data Acc. To Csa

Rated voltage (Use group B / CSA)
300 V
Rated voltage (Use group C / CSA)
50 V
Rated voltage (Use group D / CSA)
300 V
Rated current (Use group B / CSA)
11 A
Rated current (Use group C / CSA)
11 A
Rated current (Use group D / CSA)
11 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 16