Weidmuller

1352370000

VPU I 3+1 400V/12,5KA...
1352370000
1352370000
Part Number
1352370000
Free Shipping!
1
Payment methods:
Best offer from:
CZTrusted Automa.Net Supplier
Availability:
0 pcs.
On Request
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original packaging, factory sealed.
Delivery from:
IT
IT
PL
PL
Shipping Information

Available Offers (2)

1352370000 product image
Weidmuller

1352370000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
1352370000 product image
Weidmuller

1352370000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Additional Information

Part Number
1352370000

General Data

Colour
black, orange, blue
Design
Installation housing; 4TE, Insta IP 20
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
without telecomm. contact

Approvals

Approvals
CE, EAC, OEVE
ROHS
Conform

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
IV

Rated Data Iec / En

Discharge current I
20 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability I
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
250 A gL (if back up fuse > 250 A)
Leakage current at U
100 µA
Lightning test current I
12.5 kA
Lightning test current, I
50 kA
Low voltage network
TN-C-S, TN-S, TT, IT with N
Max. continuous voltage, Uc (AC)
400 V
Max. continuous voltage, Uc (N-PE)
440 V
Number of poles
4
Protection level U
≤ 2.7 kV
Rated voltage (AC)
400 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns, ≤ 100 ns
Short-circuit current rating I
25 kA
Signalling contact
No
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
620 V
Voltage type
AC

Dimensions And Weights

Width
71.2 mm
Width (inches)
2.803 inch
Height
94 mm
Height (inches)
3.701 inch
Depth
69 mm
Depth (inches)
2.717 inch
Mounting dimension - height
75 mm
Net weight
708 g

Connection Data

Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross-section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
50 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
50 mm²

Tender Specification Sheets

Long specification
Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (in accordance with IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class I surge protection systems according to the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 3+1 400/690 V/12.5 kA is used in the TN-S, IT and TT mains networks. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 230 VAC lightning test current (10/350 µs): 12.5 kA protection level with lightning test current < 1.8 kV 25 kA short-circuit withstand rating with max. back-up fuse of 250 A gl Type: Weidmüller VPU I 3+1 R 400 V/12.5 kA Order No. 1352370000
Short specification
Class I arrester for LPL III/IV with 12.5 kA suitable for 400/690 V TN-S, TT, IT mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU I 3 +1 R 400 V/12.5 kA Order no. 1352380000 or equivalent

Classifications

ETIM 6.0
EC000941
ETIM 7.0
EC000941
EClass 9.0
27-13-08-05
EClass 9.1
27-13-08-05
EClass 10.0
27-13-08-05
UNSPSC
30-21-19-22

Temperatures

Humidity
5 - 95% rel. humidity
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-40 °C...80 °C