Weidmuller

1352840000

VPU II 1 R 400V/40KA...
1352840000
1352840000
Part Number
1352840000
Free Shipping!
1
Payment methods:
Best offer from:
CZTrusted Automa.Net Supplier
Availability:
0 pcs.
On Request
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original packaging, factory sealed.
Delivery from:
IT
IT
PL
PL
Shipping Information

Available Offers (2)

1352840000 product image
Weidmuller

1352840000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
1352840000 product image
Weidmuller

1352840000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Additional Information

Part Number
1352840000

General Data

Colour
black, orange
Design
Installation housing; 1TE, Insta IP 20
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20
Rail
TS 35
UL 94 flammability rating
V-0
Version
with remote contact

Approvals

Approvals
CE, EAC, OEVE
ROHS
Conform

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
III

Rated Data Iec / En

Combined pulse U
10 kV
Discharge current I
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability I
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
125 A gL > (if back up fuse > 125 A)
Leakage current at U
150 µA
Low voltage network
Single-phase
Max. continuous voltage, Uc (AC)
400 V
Number of poles
1
Protection level U
≤ 2.1 kV
Rated voltage (AC)
400 V
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
Short-circuit current rating I
25 kA
Signalling contact
250 V 1A 1CO
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
620 V
Voltage type
AC

Dimensions And Weights

Width
17.8 mm
Width (inches)
0.701 inch
Height
106 mm
Height (inches)
4.173 inch
Depth
69 mm
Depth (inches)
2.717 inch
Mounting dimension - height
75 mm
Net weight
151 g

Connection Data

Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross-section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
50 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
50 mm²

Tender Specification Sheets

Long specification
Single-pole surge protection according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection and is used in applications according to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 1 R 400 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (changeover). Rated voltage: 400 VAC In/max (8/20 µs): 20/40 kA protection level < 2.1 kV 25 kA short-circuit strength with max. back-up fuse of 125 A gl telecommunication output: contact: 250 V/0.5 A 48 VDC/0.1 A Type: Weidmüller VPU II 1 R 400 V/40 kA Order No. 1352840000 or equivalent
Short specification
Class II arrester with In/Imax: 20/40 kA suitable for 400/690 V mains systems. Protection level < 2.1 kV. With remote alert Type: Weidmüller VPU II 1 R 400 V/40 kA Order no. 1352840000 or equivalent

Classifications

ETIM 6.0
EC000941
ETIM 7.0
EC000941
EClass 9.0
27-13-08-05
EClass 9.1
27-13-08-05
EClass 10.0
27-13-08-05
UNSPSC
30-21-19-21

Connection Data, Remote Alert

Connection type
PUSH IN
Stripping length
8 mm
Cross-section for connected wire, solid core, min.
0.14 mm²
Cross-section for connected wire, solid core, max.
1.5 mm²

Temperatures

Humidity
5 - 95% rel. humidity
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-40 °C...80 °C