A total of 20 Parts In-Stock from 8 Distributors

Approvals

Approvals
CE, CSA, cURus, DNV GL, EAC, IECEXKEM, KEMAATEX, KEMAKEUR
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Width
5.1 mm
Width (inches)
0.201 inch
Height
67 mm
Height (inches)
2.638 inch
Depth
38 mm
Depth (inches)
1.496 inch
Depth including DIN rail
39 mm
Net weight
13.82 g

Csa Rating Data

Certificate No. (CSA)
200039-1751332
Wire cross section max. (CSA)
10 AWG
Wire cross section min. (CSA)
26 AWG

Additional Technical Data

Explosion-tested version
Yes
Open sides
right
Type of mounting
Snap-on

Material Data

Material
Wemid
Colour
Green/yellow
UL 94 flammability rating
V-0

Safety Note

Safety notice
Safety Information

Classifications

ETIM 6.0
EC000901
ETIM 7.0
EC000901
EClass 9.0
27-14-11-41
EClass 9.1
27-14-11-41
EClass 10.0
27-14-11-41
UNSPSC
30-21-18-11

System Specifications

Version
PUSH IN connection, With PE connection, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
3
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
Yes
Rail
TS 35
N-function
No
PE function
Yes
PEN function
No

Temperatures

Operating temperature range
For operating temperature range see EC Design Test Certificate / IEC Ex-Certificate of Conformity
Storage temperature, max.
40 °C
Storage temperature, min.
10 °C
Storage temperature
10 °C...40 °C
Continuous operating temp., min.
-50 °C
Continuous operating temp., max.
120 °C

Pe Rating Data

Rated short-time current
480 A (4 mm²)
PEN function
No

Rating Data

Rated cross-section
4 mm²
Rated voltage to adjoining terminal
800 V
Standards
IEC 60947-7-2
Volume resistance according to IEC 60947-7-x
1 mΩ
Power loss in accordance with IEC 60947-7-x
1.02 W
Rated impulse withstand voltage to adjacent terminal
8 kV
Pollution severity
3

Rating Data Iecex/Atex

Certificate No. (ATEX)
KEMA06ATEX0177U
Certificate No. (IECEX)
IECEXKEM06.0032U
Wire cross section max. (ATEX)
4 mm²
Wire cross section max. (IECEX)
4 mm²
Operating temperature range
For operating temperature range see EC Design Test Certificate / IEC Ex-Certificate of Conformity
Marking EN 60079-7
Ex eb II C Gb
Ex 2014/34/EU label
II 2 G D

Conductors For Clamping (Rated Connection)

Blade size
3.0 x 0.5 mm
Clamping range, max.
6 mm²
Clamping range, min.
0.13 mm²
Connection direction
top
Gauge to IEC 60947-1
A3
Number of connections
3
Stripping length
12 mm
Twin wire-end ferrules, max.
1.5 mm²
Twin wire-end ferrules, min.
0.5 mm²
Type of connection
PUSH IN
Wire connection cross section AWG, max.
AWG 10
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section, finely stranded, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded, min.
0.5 mm²
Wire connection cross-section, solid core, max.
6 mm²
Wire connection cross-section, solid core, min.
0.5 mm²

Ul Rating Data

Certificate No. (cURus)
E60693
Conductor size Factory wiring max. (cURus)
10 AWG
Conductor size Factory wiring min. (cURus)
26 AWG
Conductor size Field wiring max. (cURus)
10 AWG
Conductor size Field wiring min. (cURus)
26 AWG