Weidmuller

1967220000

HDC HVE 3+2 FT CtH
1967220000
1967220000
1967220000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

General Data

Conductor cross-section
2.5 mm²
Insulating material
PC glass-fibre reinforced (UL-listed and railway-certified)
Insulating material group
IIIa
Insulation strength
1010 Ω
Material
Copper alloy
Number of poles
5
Number of power contacts
3
Number of signal contacts
2
Plugging cycles, silver
≥ 500
Pollution severity
3
Rated current (DIN EN 61984)
20 A
Rated impulse voltage (DIN EN 61984)
8 kV
Rated voltage (DIN EN 61984)
830 V
Rated voltage according to UL/CSA
600 V AC/DC
Series
HVE
Size
4
Surface finish
Silver passivated
Type
Female
UL 94 flammability rating
V-0
Volume resistance
≤ 2mΩ

Approvals

Approvals
DNV GL
ROHS
Conform

Dimensions And Weights

Width
34 mm
Width (inches)
1.339 inch
Height
33 mm
Height (inches)
1.299 inch
Depth
64 mm
Depth (inches)
2.52 inch
Net weight
50 g

General Descriptions

Number of poles
5
Size
4

Dimensions

Height of socket
33 mm
Total length base
64 mm

Version

Blade size, slotted (screw connection)
SD 0.5 x 3.0
Conductor cross-section, max.
2.5 mm²
Conductor cross-section, min.
0.25 mm²
Material
Copper alloy
Size
4
Stripping length, rated connection
8 mm
Surface finish
Silver passivated
Type of connection
Tension-clamp connection
Volume resistance
≤ 2mΩ
Wire connection cross section AWG, max.
AWG 14
Wire connection cross section AWG, min.
AWG 24
Wire connection cross section, finely stranded, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded, min.
0.5 mm²
Wire cross-section, solid, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²

Material

Insulating material
PC glass-fibre reinforced (UL-listed and railway-certified)
Colour
beige
UL 94 flammability rating
V-0
Material
Copper alloy

Connection Data

Conductor cross-section, min.
0.25 mm²
Conductor cross-section, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 24
Wire connection cross section AWG, max.
AWG 14

Connection Data Pe

Blade size, crosshead
size PH1
Blade size, slotted (PE connection)
SD 0.8 x 4.0
Connection type PE
Screw connection
Fixing screw
M 4
Rated cross-section
4 mm²
Stripping length PE connection
10 mm
Tightening torque, max. PE connection
1.5 Nm
Tightening torque, min. PE connection
1.2 Nm
Wire connection cross section, finely stranded, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded, min.
0.5 mm²
Wire cross section, AWG (PE), max.
AWG 12
Wire cross section, AWG (PE), min.
AWG 20
Wire cross-section, solid, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²

Classifications

ETIM 6.0
EC000438
ETIM 7.0
EC000438
EClass 9.0
27-44-02-05
EClass 9.1
27-44-02-05
EClass 10.0
27-44-02-05
UNSPSC
30-21-18-01

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Design

Product family
HDC insert
Product type
Insert
Type
Female
Type of connection
Tension-clamp connection
Blade size, crosshead
size PH1

Temperatures

Limit temperature
-40 °C ... 125 °C