Weidmuller

2500590000

LUFS 15.00/05/90V 5.0SN BK BX
2500590000
2500590000
2500590000
2500590000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€16.08
1
Payment methods:
A total of 20 Parts In-Stock from 8 Distributors

Rated Data Acc. To Ul 1059

Institute (cURus)
cURus
Certificate No. (cURus)
E60693
Rated voltage (Use group B / UL 1059)
600 V
Rated voltage (Use group C / UL 1059)
600 V
Rated voltage (Use group D / UL 1059)
600 V
Rated voltage (Use group E / UL 1059)
1,000 V
Rated current (Use group B / UL 1059)
53 A
Rated current (Use group C / UL 1059)
53 A
Rated current (Use group D / UL 1059)
5 A
Rated current (Use group E / UL 1059)
53 A
Wire cross-section, AWG, min.
AWG 18
Wire cross-section, AWG, max.
AWG 4
Reference to approval values
Specifications are maximum values, details - see approval certificate.

Approvals

Approvals
cURus
UL File Number Search
E60693

Dimensions And Weights

Width
71.8 mm
Width (inches)
2.827 inch
Height
35 mm
Height (inches)
1.378 inch
Height of lowest version
30 mm
Depth
28.55 mm
Depth (inches)
1.124 inch
Net weight
58.71 g

Rated Data Acc. To Iec

Rated current, min. number of poles (Tu=20°C)
76 A
Rated current, max. number of poles (Tu=20°C)
76 A
Rated current, min. number of poles (Tu=40°C)
76 A
Rated current, max. number of poles (Tu=40°C)
76 A
Rated voltage for surge voltage class / pollution degree II/2
1,000 V
Rated voltage for surge voltage class / pollution degree III/2
1,000 V
Rated voltage for surge voltage class / pollution degree III/3
1,000 V
Rated impulse voltage for surge voltage class/ pollution degree II/2
8 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2
8 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3
8 kV

Material Data

Insulating material
Wemid (PA)
Colour
black
Colour of operational elements
orange
Material of operational elements
PA4T GF
Colour chart (similar)
RAL 9011
Insulating material group
I
Comparative Tracking Index (CTI)
≥ 600
Insulation strength
≥ 108 Ω
UL 94 flammability rating
V-0
Contact material
E-Cu
Storage temperature, min.
-25 °C
Storage temperature, max.
55 °C
Max. relative humidity during storage
80 %
Operating temperature, min.
-40 °C
Operating temperature, max.
120 °C

Classifications

ETIM 6.0
EC002643
ETIM 7.0
EC002643
EClass 9.0
27-44-04-01
EClass 9.1
27-44-04-01
EClass 10.0
27-44-04-01

System Parameters

Product family
OMNIMATE Power - series LU
Wire connection method
PUSH IN without actuator
Mounting onto the PCB
THT solder connection
Conductor outlet direction
90°
Pitch in mm (P)
15 mm
Pitch in inches (P)
0.591 inch
Number of poles
5
Fitted by customer
No
Number of rows
1
Solder pin length (l)
5 mm
Solder pin dimensions
d = 1.2 mm, Octagonal
Solder eyelet hole diameter (D)
1.7 mm
Solder eyelet hole diameter tolerance (D)
+ 0,1 mm
Number of solder pins per pole
2
Screwdriver blade
0.8 x 4.0
Stripping length
18 mm
L1 in mm
60 mm
L1 in inches
2.362 inch
Touch-safe protection acc. to DIN VDE 0470
IP20 plugged/ IP10 unplugged
Touch-safe protection acc. to DIN VDE 57 106
touch-safe with connected connectors from 6 mm²
Insulation strength
≥ 108 Ω

Packing

Packaging
Box
VPE length
320 mm
VPE width
170 mm
VPE height
55 mm

Notes

Notes
Additional colours on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point.
IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.

Conductors Suitable For Connection

Clamping range, min.
0.5 mm²
Clamping range, max.
16 mm²
Wire connection cross section AWG, min.
AWG 18
Wire connection cross section AWG, max.
AWG 4
Solid, min. H05(07) V-U
0.5 mm²
Solid, max. H05(07) V-U
16 mm²
Stranded, min. H07V-R
10 mm²
Stranded, max. H07V-R
16 mm²
Flexible, min. H05(07) V-K
0.5 mm²
Flexible, max. H05(07) V-K
16 mm²
W. plastic collar ferrule, DIN 46228 pt 4, min.
0.5 mm²
W. plastic collar ferrule, DIN 46228 pt 4, max.
16 mm²
W. wire end ferrule, DIN 46228 pt 1, min.
0.5 mm²
W. wire end ferrule, DIN 46228 pt 1, max.
16 mm²
Max. clamping range
16 mm²

Rated Data Acc. To Csa

Rated voltage (Use group B / CSA)
600 V
Rated voltage (Use group C / CSA)
600 V
Rated voltage (Use group D / CSA)
600 V
Rated current (Use group B / CSA)
53 A
Rated current (Use group C / CSA)
53 A
Rated current (Use group D / CSA)
5 A
Wire cross-section, AWG, min.
AWG 18
Wire cross-section, AWG, max.
AWG 4