Weidmuller

2618140000

TRP 60VUC 1CO
2618140000
2618140000
2618140000
2618140000
2618140000
2618140000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

General Data

Rail
TS 35
Test button
No
Mechanical switch position indicator
No
Colour
black
UL 94 flammability rating
V-0

Approvals

Approvals
CULUS
UL File Number Search
E141197

Dimensions And Weights

Width
6.4 mm
Width (inches)
0.252 inch
Height
89.4 mm
Height (inches)
3.52 inch
Depth
87.8 mm
Depth (inches)
3.457 inch
Net weight
0 g

Connection Data

Wire connection method
PUSH IN with actuator
Stripping length, rated connection
8 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.14 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.14 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross-section, finely stranded, min.
0.14 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 14
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.15 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.15 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Twin wire-end ferrules, min.
0.5 mm²
Twin wire-end ferrules, max.
1 mm²
Blade size
0.4 x 2.0 mm

Contact Data

Contact type
1 CO contact (AgNi)
Mechanical service life
5 x 106 switching cycles

Input

Rated control voltage
60 V UC ± 10 %
Rated current AC
4,8 mA
Rated current DC
2.8 mA
Power rating
170 mW, 290 mVA
Pull-in/drop-out voltage, typ.
33 V / 8 V AC 41.5 V / 9 V DC
Pull-in/drop-out current, typ.
2.8 mA / 0.6 mA AC 1.8 mA / 0.3 mA DC
Status indicator
Green LED
Protective circuit
Rectifier
Coil voltage of the replacement relay deviating from the rated control voltage
Yes
Coil voltage of the replacement relay
60 V DC

Classifications

ETIM 6.0
EC001437
ETIM 7.0
EC001437
EClass 9.0
27-37-16-01
EClass 9.1
27-37-16-01
EClass 10.0
27-37-16-01

Output

Rated switching voltage
250 V AC
Max. switching voltage, AC
250 V
Max. switching voltage, DC
250 V
Continuous current
6 A
Inrush current
20 A / 20 ms
AC switching capacity (resistive), max.
1500 VA
DC switching capacity (resistive), max.
144 W @ 24 V
Switch-on delay
≤ 7 ms
Switch-off delay
≤ 50 ms
Min. switching power
1 mA @ 24 V, 10 mA @ 12 V, 100 mA @ 5 V
Max. switching frequency at rated load
0.1 Hz

Insulation Coordination

Rated voltage
300 V
Surge voltage category
III
Pollution severity
2
Protection degree
IP20
Dielectric strength, Input/Output
4 kVeff / 1 Min.
Creepage and clearance distance input – output
≥ 5.5 mm
Dielectric strength of open contact
1 kVeff / 1 min
Dielectric strength to mounting rail
4 kVeff / 1 Min.
Impulse withstand voltage
6 kV (1.2/50 µs)

Temperatures

Humidity
5-95% relative humidity, Tu = 40°C, without condensation
Operating temperature, max.
60 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...60 °C
Storage temperature
-40 °C...85 °C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197

Further Details Of Approvals / Standards

Standards
EN 50178, EN 55011, EN 61000-6-1, 2, 4
Certificate no. (cULus)
E141197