Weidmuller
7760054121
ACT20P-VI-CO-OLP
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€108.36
Additional Information
- Part Number
- 7760054121
General Data
- Accuracy
- < 0.2 % of end value
- Configuration
- none
- Galvanic isolation
- 2-way isolator
- Rail
- TS 35
- Step response time
- ≤ 1 ms
- Temperature coefficient
- ≤ 100 ppm/K
- Voltage supply
- via output current loop, min. 12 V DC/ max. 30 V DC
Approvals
- Approvals
- EAC
Dimensions And Weights
- Width
- 12.5 mm
- Width (inches)
- 0.492 inch
- Height
- 117.2 mm
- Height (inches)
- 4.614 inch
- Depth
- 114 mm
- Depth (inches)
- 4.488 inch
- Weight
- 126 g
- Net weight
- 100 g
Connection Data
- Type of connection
- Screw connection
- Tightening torque, min.
- 0.4 Nm
- Tightening torque, max.
- 0.6 Nm
- Clamping range, rated connection
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section AWG, max.
- AWG 12
Input
- Number of inputs
- 1
- Sensor
- Voltage source
- Input voltage
- 0...10 V
- Input resistance, voltage
- ≥ 300 kΩ
Classifications
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- EClass 9.0
- 27-21-01-20
- EClass 9.1
- 27-21-01-20
- EClass 10.0
- 27-21-01-20
Output
- Number of outputs
- 1
- Output current
- 4...20 mA, loop-powered
- Load impedance current
- ≤ 600 Ω
Product Information
- Product information
- The ACT20P-VIX-CO-OLP-S single-channel fixed passive isolator isolates and converts analogue standard signals. An analogue input voltage signal is linearly converted into an analogue output current signal and galvanically isolated. The device is powered via the output current loop. Features 2-way galvanic isolation between input and output.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- EMC standards
- EN 61010-1:2011, UL 61010-1, IEC61000-6-2, IEC 61000-6-4
- Galvanic isolation
- 2-way isolator
- Impulse withstand voltage
- 4 kV (1.2/50 µs)
- Insulation voltage
- 2 kV (Input /Output), 1 min, 50 Hz
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Temperatures
- Humidity
- 5...95 %, no condensation
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- -20 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -20 °C...60 °C
- Ambient temperature
- -20 °C...+60 °C
- Storage temperature
- -40 °C...85 °C
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther